137 / 212 page ![]() out 137/212 ® out output message Code: FB Description: Output a message (where the corresponding input is performed by an in instruction, and must specify a message of the same length). Areg is the unsigned length, Breg is a pointer to the channel, and Creg is a pointer to the message. The process executing out will be descheduled if the channel is external or is not ready; it is rescheduled when the communication is complete. This instruction is also used to synchronize with an alternative. Definition: Synchronize, and output Aregunsigned bytes to channel Breg from address Creg Areg ′← undefined Breg ′← undefined Creg ′← undefined Error signals: Can cause InternalChannel or ExternalChannel trap to be signalled (if enabled) when the process is rescheduled on synchronization. Comments: Secondary instruction. See also: altwt enbc in outbyte outword |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|