| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
PIC18F4331 Datasheet(PDF) 309 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC18F4331 Datasheet(HTML) 309 Page - Microchip Technology |
|
309 / 396 page ![]() 2003 Microchip Technology Inc. Preliminary DS39616B-page 307 PIC18F2331/2431/4331/4431 DECFSZ Decrement f, skip if 0 Syntax: [ label ] DECFSZ f [,d [,a]] Operands: 0 ≤ f ≤ 255 d ∈ [0,1] a ∈ [0,1] Operation: (f) – 1 → dest, skip if result = 0 Status Affected: None Encoding: 0010 11da ffff ffff Description: The contents of register ‘f’ are dec- remented. If ‘d’ is 0, the result is placed in W. If ‘d’ is 1, the result is placed back in register ‘f’ (default). If the result is 0, the next instruc- tion, which is already fetched, is discarded, and a NOP is executed instead, making it a two-cycle instruction. If ‘a’ is 0, the Access Bank will be selected, overriding the BSR value. If ‘a’ = 1, then the bank will be selected as per the BSR value (default). Words: 1 Cycles: 1(2) Note: 3 cycles if skip and followed by a 2-word instruction. Q Cycle Activity: Q1 Q2 Q3 Q4 Decode Read register ‘f’ Process Data Write to destination If skip: Q1 Q2 Q3 Q4 No operation No operation No operation No operation If skip and followed by 2-word instruction: Q1 Q2 Q3 Q4 No operation No operation No operation No operation No operation No operation No operation No operation Example: HERE DECFSZ CNT GOTO LOOP CONTINUE Before Instruction PC = Address (HERE) After Instruction CNT = CNT - 1 If CNT = 0; PC = Address (CONTINUE) If CNT ≠ 0; PC = Address (HERE+2) DCFSNZ Decrement f, skip if not 0 Syntax: [ label ] DCFSNZ f [,d [,a]] Operands: 0 ≤ f ≤ 255 d ∈ [0,1] a ∈ [0,1] Operation: (f) – 1 → dest, skip if result ≠ 0 Status Affected: None Encoding: 0100 11da ffff ffff Description: The contents of register ‘f’ are dec- remented. If ‘d’ is 0, the result is placed in W. If ‘d’ is 1, the result is placed back in register ‘f’ (default). If the result is not 0, the next instruction, which is already fetched, is discarded, and a NOP is executed instead, making it a two- cycle instruction. If ‘a’ is 0, the Access Bank will be selected, overriding the BSR value. If ‘a’ = 1, then the bank will be selected as per the BSR value (default). Words: 1 Cycles: 1(2) Note: 3 cycles if skip and followed by a 2-word instruction. Q Cycle Activity: Q1 Q2 Q3 Q4 Decode Read register ‘f’ Process Data Write to destination If skip: Q1 Q2 Q3 Q4 No operation No operation No operation No operation If skip and followed by 2-word instruction: Q1 Q2 Q3 Q4 No operation No operation No operation No operation No operation No operation No operation No operation Example: HERE DCFSNZ TEMP ZERO : NZERO : Before Instruction TEMP = ? After Instruction TEMP = TEMP - 1, If TEMP = 0; PC = Address (ZERO) If TEMP ≠ 0; PC = Address (NZERO) |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |