| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
PIC18F4331 Datasheet(PDF) 155 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC18F4331 Datasheet(HTML) 155 Page - Microchip Technology |
|
155 / 396 page ![]() 2003 Microchip Technology Inc. Preliminary DS39616B-page 153 PIC18F2331/2431/4331/4431 15.3 Capture Mode In Capture mode, CCPR1H:CCPR1L captures the 16- bit value of the TMR1 register when an event occurs on pin RC2/CCP1. An event is defined as one of the following: • every falling edge • every rising edge • every 4th rising edge • every 16th rising edge The event is selected by control bits CCP1M3:CCP1M0 (CCP1CON<3:0>). When a capture is made, the interrupt request flag bit CCP1IF (PIR1<2>) is set; it must be cleared in software. If another capture occurs before the value in register CCPR1 is read, the old captured value is overwritten by the new captured value. 15.3.1 CCP PIN CONFIGURATION In Capture mode, the RC2/CCP1 pin should be configured as an input by setting the TRISC<2> bit. 15.3.2 TIMER1 MODE SELECTION Timer 1 must be running in Timer mode or Synchro- nized Counter mode to be used with the capture fea- ture. In Asynchronous Counter mode, the capture operation may not work. 15.3.3 SOFTWARE INTERRUPT When the Capture mode is changed, a false capture interrupt may be generated. The user should keep bit CCP1IE (PIE1<2>) clear to avoid false interrupts and should clear the flag bit, CCP1IF, following any such change in operating mode. 15.3.4 CCP PRESCALER There are four prescaler settings, specified by bits CCP1M3:CCP1M0. Whenever the CCP module is turned off or the CCP module is not in Capture mode, the prescaler counter is cleared. This means that any Reset will clear the prescaler counter. Switching from one capture prescaler to another may generate an interrupt. Also, the prescaler counter will not be cleared, therefore, the first capture may be from a non-zero prescaler. Example 15-1 shows the recom- mended method for switching between capture pres- calers. This example also clears the prescaler counter and will not generate the “false” interrupt. EXAMPLE 15-1: CHANGING BETWEEN CAPTURE PRESCALERS FIGURE 15-1: CAPTURE MODE OPERATION BLOCK DIAGRAM Note: If the RC2/CCP1 is configured as an out- put, a write to the port can cause a capture condition. CLRF CCP1CON, F ; Turn CCP module off MOVLW NEW_CAPT_PS ; Load WREG with the ; new prescaler mode ; value and CCP ON MOVWF CCP1CON ; Load CCP1CON with ; this value CCPR1H CCPR1L TMR1H TMR1L Set Flag bit CCP1IF Q’s CCP1CON<3:0> CCP1 pin Prescaler ÷ 1, 4, 16 and Edge Detect TMR1 Enable CCPR2H CCPR2L TMR1H TMR1L Set Flag bit CCP2IF Q’s CCP2CON<3:0> CCP2 pin Prescaler ÷ 1, 4, 16 and Edge Detect TMR1 Enable |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |