Motor de Búsqueda de Datasheet de Componentes Electrónicos
  Mexican  ▼
ALLDATASHEET.COM.MX

X  

  • E5CS-R2

  • AI
    ## Overview of Omron E5CS-R2 Temperature Controller The **Omron E5CS-R2** is a compact, digital temperature controller designed for industrial DIN-sized applications (48x48mm). It is part of the E5CS series, known for its "easy-to-set" rotary switches and basic functionality. ### 1. Key Technical Specifications | Feature | Specification | | :--- | :--- | | **Control Output** | Relay Output (SPDT, 250 VAC, 3A) | | **Input Type** | Thermocouple (Type K, J, L) or Platinum RTD (Pt100, JPt100) | | **Supply Voltage** | 100 to 240 VAC (50/60 Hz) | | **Alarm Output** | 1 Relay Output (R2 suffix indicates two relays: Control + Alarm) | | **Control Mode** | ON/OFF or proportional (P) control | | **Panel Size** | 1/16 DIN (48 x 48 mm) | --- ### 2. Electronic Components & Internal Architecture The E5CS-R2 consists of several critical electronic stages to process thermal signals and manage power: #### A. Input Conditioning (Sensor Interface) * **Cold Junction Compensation (CJC):** For thermocouple models, an internal thermistor measures the terminal temperature to compensate for the voltage generated at the junction. * **A/D Converter:** A high-precision Analog-to-Digital converter translates the millivolt signal (from thermocouples) or resistance change (from RTDs) into digital data. #### B. Control Logic (Microcontroller) * **MCU:** A dedicated microprocessor compares the **Process Value (PV)** against the **Set Value (SV)**. * **Rotary Switches:** Unlike modern digital menus, the E5CS uses physical rotary switches (accessible via the front panel) to set the temperature range and control parameters. #### C. Power Supply Section * **Switching Mode Power Supply (SMPS):** Converts 100-240V AC line voltage to low-voltage DC (typically 5V or 12V) to power the internal logic and the output relay coil. * **Isolation:** Optical or magnetic isolation is used between the high-voltage power side and the sensitive input sensor side to prevent electrical noise interference. #### D. Output Stage (The "R" in R2) * **Electromechanical Relays:** The "R" designates **Relay** output. * **Main Relay:** Rated for 3A, used to trigger a contactor or a small heater. * **Alarm Relay:** A secondary relay that closes when a specific deviation or absolute temperature threshold is met. --- ### 3. Connection Terminal Map Typical wiring for the E5CS-R2 involves the following terminals: | Terminal No. | Function | Description | | :--- | :--- | :--- | | **1 & 2** | AC Power | 100 - 240 VAC Input | | **3, 4, 5** | Control Output | Relay (Common, NO, NC) | | **7, 8, 9** | Sensor Input | Thermocouple or RTD (A, B, B') | | **10 & 11** | Alarm Output | Relay contact for safety/alert | --- ### 4. Comparison: E5CS-R2 vs. E5CS-Q2 * **E5CS-R2:** Uses a physical **Relay** (Mechanical). Best for controlling contactors. * **E5CS-Q2:** Uses a **Voltage Output** (12VDC). Best for driving Solid State Relays (SSRs) for high-speed switching.
    ✨ Follow-up Questions
    • ⤷ How do you set the temperature range on an E5CS using the rotary switches?
    • ⤷ What is the difference between J-type and K-type thermocouple inputs on this device?
    • ⤷ Can the E5CS-R2 be used for PID control or only ON/OFF control?