FRS-R-150
AI

The **FRS-R-150** is a specific model of a high-capacity industrial fuse. It belongs to the **Fusetron™** series manufactured by Bussmann (a division of Eaton).
Below is a detailed breakdown of its electronic specifications and characteristics.
---
### 1. Technical Specifications
The FRS-R-150 is a Class RK5, current-limiting, dual-element time-delay fuse.
| Property | Specification |
| :--- | :--- |
| **Current Rating** | 150 Amps |
| **Voltage Rating (AC)** | 600 Vac |
| **Voltage Rating (DC)** | 300 Vdc |
| **Interrupting Rating (AC)** | 200,000 Amps RMS Symmetrical |
| **Interrupting Rating (DC)** | 20,000 Amps |
| **Class** | RK5 |
| **Fuse Body Material** | Fiberglass tube |
| **Mounting Style** | Blade / Bolt-on |
---
### 2. Key Electronic Features
#### A. Dual-Element Design
Unlike standard fast-acting fuses, the FRS-R-150 contains two distinct elements:
1. **Thermal Element:** Handles low-level overloads. It provides a "time-delay" (typically 10 seconds at 500% of the rated current), allowing motors to start without blowing the fuse due to inrush current.
2. **Magnetic Element:** Handles short-circuit events. It reacts instantly to high-magnitude faults to prevent equipment damage.
#### B. Current Limiting
This fuse is "current-limiting," meaning it can interrupt a fault current before it reaches its peak magnitude. This significantly reduces the thermal and magnetic stress on downstream electrical components during a short circuit.
#### C. Rejection Feature (The "-R" Suffix)
The "R" in FRS-R indicates a **rejection tip**. This is a physical notch in the blade that ensures it can only be installed in a Class R fuse holder. This prevents a lower-rated fuse (like a Class H) from being mistakenly installed in a circuit that requires high-interrupting capacity.
---
### 3. Common Applications
Due to its 150A rating and time-delay characteristics, the FRS-R-150 is primarily used in:
* **Motor Branch Circuits:** Protection for large industrial motors where startup current is high.
* **Transformers:** Handling magnetization inrush currents.
* **Main Service Disconnects:** Used as a primary safety layer for industrial control panels.
* **General Purpose Feeder Circuits:** Protecting wiring from overloads.
---
### 4. Identification and Safety
When replacing this part, ensure the following markings are visible on the label:
* **UL Listed:** Standard for safety.
* **Green Labeling:** Typically signifies the Fusetron™ brand identity for Class RK5 fuses.
* **Ampere Rating:** Clearly marked as "150A".
- ⤷What is the difference between a Class RK1 and a Class RK5 fuse like the FRS-R-150?
- ⤷ How do I test if an FRS-R-150 fuse is blown using a multimeter?
- ⤷ Can I use an FRS-R-150 in a 480V three-phase motor application?