M2VT-1A-R2
AI

The **M2VT-1A-R2** is a high-performance **Transducer (Signal Conditioner)** manufactured by **M-System** (now part of MG CO., LTD). Its primary function is to convert a variable frequency input signal into a standard analog output signal (DC voltage or current).
---
### ## Technical Specifications Overview
| Feature | Specification |
| :--- | :--- |
| **Model** | M2VT-1A-R2 |
| **Primary Function** | Frequency to DC Transmitter |
| **Input Signal** | Dry contact, open collector, voltage pulse |
| **Output Signal** | 4 – 20 mA DC |
| **Power Input** | 24V DC |
| **Isolation** | 3-way isolation (input to output to power) |
| **Mounting** | DIN Rail / Surface mount |
---
### ## Electronic Components & Functional Blocks
The device is composed of several critical electronic stages that ensure signal integrity and accuracy:
#### 1. Input Circuitry (Signal Conditioner)
The input stage is designed to handle various pulse types. It includes a **noise filter** and a **comparator** to detect frequency thresholds.
* **Sensitivity Adjustment:** It can distinguish between low-voltage logic pulses and high-voltage spikes.
* **Pulse Integration:** It counts the incoming pulses over a specific time window to determine the frequency.
#### 2. Isolation Barrier
This is a "3-way isolated" device. It uses **Opto-couplers** or **Transformers** to separate the input, output, and power circuits.
* **Benefit:** Prevents ground loops and protects sensitive PLC/DCS equipment from high-voltage surges on the sensor side.
#### 3. Signal Conversion (F/V or F/I)
The core logic utilizes a Frequency-to-Voltage (F/V) converter. The internal microprocessor or specialized IC calculates the frequency ($Hz$) and maps it linearly to the designated output range (e.g., 4mA at 0Hz and 20mA at the maximum frequency).
#### 4. Output Stage
A **Current Loop Driver** ensures that the 4-20mA signal remains stable even if the resistance of the connection wire changes. This stage uses high-precision operational amplifiers and transistors to maintain the current loop.
---
### ## Pin Configuration (Typical)
| Pin No. | Function | Description |
| :--- | :--- | :--- |
| **1 & 2** | Output (+) / (-) | 4-20mA DC Signal |
| **3 & 4** | Input (+) / (-) | Frequency source (e.g., Flow meter) |
| **5 & 6** | Power (+) / (-) | 24V DC Supply |
---
### ## Applications
* **Flow Measurement:** Converting pulses from a turbine flow meter into a 4-20mA signal for a PLC.
* **Motor Speed:** Monitoring RPM via a proximity switch or encoder.
* **Power Grid Monitoring:** Measuring AC frequency variations.
- ⤷
How do you calibrate the zero and span on the M2VT-1A-R2?
- ⤷ What is the maximum frequency range this model can handle?
- ⤷ Can this device operate with an AC power supply instead of 24V DC?