Back Button VIPER318HDTR Datasheet HTML 14Page - STMicroelectronics VIPER318HDTR Datasheet HTML 15Page - STMicroelectronics VIPER318HDTR Datasheet HTML 16Page - STMicroelectronics VIPER318HDTR Datasheet HTML 17Page - STMicroelectronics VIPER318HDTR Datasheet HTML 18Page - STMicroelectronics VIPER318HDTR Datasheet HTML 19Page - STMicroelectronics VIPER318HDTR Datasheet HTML 20Page - STMicroelectronics VIPER318HDTR Datasheet HTML 21Page - STMicroelectronics VIPER318HDTR Datasheet HTML 22Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 40 page
background image
This kind of operation, together with the extremely low IC quiescent current, allows very low input power
consumption in no-load and light load, while the low DRAIN peak current value, IDLIM_PFM, prevents any
audible noise which could arise from low switching frequency values. When the output load is increased, VCOMP
increases and PFM is exited. VCOMP reaches its maximum at VCOMPH, corresponding to the DRAIN current
limitation (IDLIM).
4.11
Overload protection
In order to manage the overload condition the IC embeds the following main blocks: the OCP comparator to turn
off the power MOSFET when the drain current reaches its limit (IDLIM), the up and down OCP counter to define
the turn-off delay time in case of continuous overload (tOVL = 50 ms typ.) and the timer to define the restart time
after protection tripping (tRESTART = 1 sec, typ.).
In case of short-circuit or overload, the control level on the inverting input of the PWM comparator is greater than
the reference level fed into the inverting input of the OCP comparator. As a result, the cycle-by-cycle turn off of the
power switch is triggered by the OCP comparator instead of by the PWM comparator. Every cycle this condition is
met, the OCP counter is incremented. If the fault condition persists for a time greater than tOVL (corresponding to
the counter end-of-count), the protection is tripped, the PWM is disabled for tRESTART, then it resumes switching
with soft-start and, if the fault is still present, it is disabled again after tOVL. The OLP management prevents the IC
from being indefinitely operated at IDLIM and the low repetition rate of the restart attempts of the converter avoids
overheating the IC in case of repeated fault events.
After the fault removal, the IC resumes working normally. If the fault is removed before the protection tripping
(before tOVL), the tOVL counter is decremented on a cycle-by-cycle basis down to zero and the protection is not
tripped. If the fault is removed during tRESTART, the IC waits for the tRESTART period ot have elapsed before
resuming switching.
In fault condition, VCC is kept between VCSon and VCCon by the periodical activation of the HV current source,
which recharges the VCC capacitor to VCcon any time the IC internal consumption discharges it to VCson.
Figure 28. Overload protection
time
VCC
VCCon
VCSon
IDRAIN
IDLIM
tOVL
tRESTART
tSS
tOVL
Overload applied
tSS
time
Overload removed
tRESTART
4.12
Undervoltage protection
If the voltage across the UVP pin (VUVP) falls below the internal threshold VUVP_th (0.4 V typ.) for a time greater
than tUVP_DEB (30 ms, typ.), the IC is disabled and its consumption is reduced to ultra-low values (Iq_DIS).
When VUVP rises above VUVP_th, the IC must wait tUVP_REST (30 ms, typ.) before resuming switching.
Both tUVP_DEB and tUVP_REST are intended to filter out possible noises/disturbances of the line, which could affect
the correct operation of the function. They are obtained through two separate up/down counters:
DEB (REST) up/down counter has a deb_eoc (rest_eoc) end-of-count. The operation is illustrated in
Figure 29. UVP timing.
If the counter starts from zero and counts always up, end-of-count is reached in a time interval tUVP_DEB
(tUVP_REST).
VIPER31
Overload protection
DS13285 - Rev 3
page 18/40



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com