194 / 205 page ![]() AD9546 Data Sheet Rev. 0 | Page 194 of 205 TIME STAMP MEASUREMENT The AD9546 is particularly well suited for applications requiring the measurement of clock frequencies and clock timing offsets. Measurement of frequency and time offset is made possible by digitizing (time stamping) input clock edges using TDCs. Each of the four primary reference inputs (REFA, REFAA, REFB, REFBB) and four auxiliary reference inputs (auxiliary REF0, auxiliary REF1, auxiliary REF2, and auxiliary REF3) of the AD9546 has a dedicated TDC (see Figure 130). The AD9546 embodies a user time stamp capturing system that gives the user access to time stamps generated by the TDCs (see the User Time Stamper (UTS) section). The UTS system embodies nine time stamp capturing units (UTS 0 to UTS 8), making it possible to capture time stamps from all eight input time stamp sources (REFx and auxiliary REFx) concurrently. The UTS system stores captured time stamps in the UTS FIFO, which the user accesses via the serial port (see the UTS Readback FIFO section). The FIFO has limited capacity, which means if the time stamp arrival rate to the FIFO exceeds the FIFO extraction rate (on average), the FIFO eventually overflows. Because a FIFO overflow causes the FIFO to stop accepting time stamps from the UTSs, the user must extract the FIFO contents at an average rate that exceeds the average time stamp arrival rate to the FIFO (otherwise, time stamps are lost). Thus, the serial port read rate puts an upper limit on the time stamp arrival rate to the FIFO. REFA TDC REFAA TDC REFB TDC REFBB TDC TDC Mx PIN MATRIX AUX REF0 AUX REF1 AUX REF2 AUX REF3 TDC TDC TDC M0 M1 M2 M3 M4 SDO/M5 CSB/M6 DIGITAL CROSS POINT MUX UTS 0 UTS FIFO SERIAL PORT SPI/I2C AD9546 TIME STAMPS CONTROLLER UTS 1 UTS 2 UTS 3 UTS 4 UTS 5 UTS 6 UTS 7 UTS 8 TIME STAMPS UP TO 8 CLOCK INPUTS Figure 130. Time Stamp Measurement Application |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |