4 / 5 page ![]() MODEL: MAT2 MAT2 SPECIFICATIONS ES-8149 Rev.12 Page 4/5 https://www.m-system.co.jp/ POWER SYSTEM Power System (example) SPD Single-phase/2-wire 220V AC MAT2–240x Single-phase/2-wire 110V AC MAT2–240x SPD Single-phase/2-wire 220V AC MAT2–4404x Single-phase/2-wire 110V AC MAT2–240x Single-phase/3-wire 400/200V AC MAT2–4404x Single-phase/3-wire 220/110V AC MAT2–240x SPD Single-phase/2-wire Generator or transformer Generator or transformer SPD MAT2–4404x MAT2–240x Three phase/3-wire (delta connection) (N) Protected device G 2 1 PE N A1 C A2 3 SPD Alarm output Circuit breaker *1. For TT system, in order to ensure safe failure mode at TOV due to earth fault on high-voltage systems, connect between terminal 2 and N of the MAT2. *2. For TT system, in order to ensure safe failure mode at TOV due to earth fault on high-voltage systems, install a four-pole (three-pole plus neutral) circuit breaker. *3. For 440V AC three-phase/3-wire system, use a residual current circuit breaker with overcurrent protection. *4. For single-phase/2-wire system, connect lines to terminal 1 and 2 of the MAT2. For single-phase/3-wire system, connect the neutral line to terminal 2 of the MAT2. Three-phase/4-wire 400V AC MAT2–4404x Three-phase/4-wire 220V AC MAT2–2404x Protected device G 2 1 PE N A1 C A2 3 SPD Alarm output Circuit breaker N Power System (example) Power System (example) Power System (example) CONNECTION EXAMPLE CONNECTION EXAMPLE POWER SYSTEM Three-phase/3-wire 400V AC Three-phase/3-wire 220V AC Three-phase/4-wire (star connection) Single-phase/2-wire (three-phase delta connection earthed in the middle of phases) *3 *1 Generator or transformer (N) Protected device G 2 1 PE N A1 C A2 3 SPD Alarm output Circuit breaker *1 Generator or transformer N Protected device G 2 1 PE N A1 C A2 3 SPD Alarm output Circuit breaker *1 *4 Single-phase/3-wire *2 ■ ALARM OUTPUT When the alarm output is to be transmitted remotely via outdoor cables, a surge protector for the signal line is required. *1 *1 *1 *3 *2 ■ CONNECTION EXAMPLES BY POWER SYSTEMS Abnormal voltages appearing in case of a light load or a fault earth loop must be within the maximum continuous operational voltage when selecting the MAT2 models. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |