| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
SHT85 Datasheet(PDF) 13 Page - Sensirion AG Switzerland |
|
|
|||||||||||||||||||||||||||||
SHT85 Datasheet(HTML) 13 Page - Sensirion AG Switzerland |
|
13 / 23 page ![]() www.sensirion.com Version 3 – August 2020 13/23 4.10 Reset A system reset of the SHT85 can be generated externally by issuing a command (soft reset). Additionally, a system reset is generated internally during power-up. During the reset procedure the sensor will not process commands. Interface Reset If communication with the device is lost, the following signal sequence will reset the serial interface: While leaving SDA high, toggle SCL nine or more times. This must be followed by a Transmission Start sequence preceding the next command. This sequence resets the interface only. The status register preserves its content. Soft Reset / Re-Initialization The SHT85 provides a soft reset mechanism that forces the system into a well-defined state without removing the power supply. When the system is in idle state the soft reset command can be sent to the SHT85. This triggers the sensor to reset its system controller and reloads calibration data from the memory. In order to start the soft reset procedure the command as shown in Table 13 should be sent. It is worth noting that the sensor reloads calibration data prior to every measurement by default. Command Hex Code Soft Reset 0x30A2 Table 13: Soft reset command (Clear blocks are controlled by the microcontroller, grey blocks by the sensor). Reset through General Call Additionally, a reset of the sensor can also be generated using the “general call” mode according to I2C-bus specification15. It is important to understand that a reset generated in this way is not device specific. All devices on the same I2C bus that support the general call mode will perform a reset. Additionally, this command only works when the sensor is able to process I2C commands. The appropriate command consists of two bytes and is shown in Table 14. Command Code Address byte 0x00 Second byte 0x06 Reset command using the general call address 0x0006 Table 14: Reset through the general call address (Clear blocks are controlled by the microcontroller, grey blocks by the sensor). Hard Reset A hard reset is achieved by switching the supply voltage to the VDD Pin off and then on again. In order to prevent powering the sensor over the ESD diodes, the voltage to pins 1 (SCL) and 4 (SDA) also needs to be removed. S General Call Address 1 2 3 4 5 6 7 8 9 Reset Command 1 2 3 4 5 6 7 8 9 General Call 1st byte General Call 2nd byte |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |