| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
KFD2-EB2.R4A.B.SP Datasheet(PDF) 1 Page - Pepperl+Fuchs Inc. |
|
|
|||||||||||||||||||||||||||||
KFD2-EB2.R4A.B.SP Datasheet(HTML) 1 Page - Pepperl+Fuchs Inc. |
|
1 / 4 page ![]() Redundant Power Feed Module KFD2-EB2.R4A.B.SP < Interface for Power Rail < Used for redundant configuration < Supply current ≤ 4 A < Replaceable fuse < Relay contact output, reversible < LED status indication < Connection via spring terminals with push-in connection technology Power feed module with spring terminals, redundant supply Function The power feed module supplies the Power Rail with a voltage of 24 V DC and a maximum current of 4 A. The device is designed for applications requiring redundant power. In the event of a device fault or a wiring fault of any isolator on the Power Rail, the collective error messaging relay alerts the controller via a binary I/O point. This relay can be configured as normally-open or normally-closed. A green LED on the front of the device indicates the power state, and a red LED lights up during a fault condition. Additionally, the bus implemented in the Power Rail is forwarded to the terminals 13 and 15 for usage with the RS-485 connection of the KFD2-WAC2-Ex1.D device. Terminal 14 is only for test purposes. In the sense of functional safety (SIL) the device provides no dangerous failures. Thereby the safe condition of the supplied isolators must be defined as the de-energized state. Thus the device will not influence the safety calculation or the SIL value. This device is compatible with all versions of the Power Rail and provides group fusing. Note: Redundant systems require 2 KFD2-EB.R4A.B power feed modules. Connection KFD2-EB2.R4A.B.SP 14 13 15 7 10 24 V DC 9- 12- 8+ 11+ Power Rail 24V DC Fault Bus 5 AT Bus Zone 2 Fault Technical Data Supply Connection terminals 11+, 12- terminals 8+, 9- Rated voltage Ur 20 ... 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded. Fusing 5 AT/250 V AC recommended maximum utilization of the fuse: 80 % Power dissipation ≤ 2.4 W 1 Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091 www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com |
Número de pieza similar - KFD2-EB2.R4A.B.SP |
|
Descripción similar - KFD2-EB2.R4A.B.SP |
|
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |