| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ADM708ARMZ Datasheet(PDF) 5 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM708ARMZ Datasheet(HTML) 5 Page - Analog Devices |
|
5 / 12 page ![]() Data Sheet ADM705/ADM706/ADM707/ADM708 Rev. H | Page 5 of 12 PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS RESET ADM705/ ADM706 TOP VIEW (Not to Scale) 1 2 3 4 5 8 7 6 MR PFO WDI WDO VCC GND PFI Figure 3. ADM705/ADM706 PDIP/SOIC Pin Configuration RESET ADM707/ ADM708 TOP VIEW (Not to Scale) 1 2 3 4 5 8 7 6 MR PFO NC VCC GND PFI NC = NO CONNECT RESET Figure 4. ADM707/ADM708 PDIP/SOIC Pin Configuration PFO ADM708 TOP VIEW (Not to Scale) 1 2 3 4 5 8 7 6 RESET GND PFI NC RESET MR VCC NC = NO CONNECT Figure 5. ADM708 MSOP Pin Configuration Table 3. Pin Function Descriptions Mnemonic Pin Number Description ADM705/ ADM706 (PDIP, SOIC) ADM707/ ADM708 (PDIP, SOIC) ADM708 (MSOP) MR 1 1 3 Manual Reset Input. When this pin is taken below 0.8 V, a reset is generated. MR can be driven from TTL, CMOS logic, or from a manual reset switch as it is internally debounced. An internal 250 μA pull-up current holds the input high when floating. VCC 2 2 4 5 V Power Supply Input. Place a 0.1 μF decoupling capacitor between the VCC and GND pins. GND 3 3 5 0 V Ground Reference for All Signals. PFI 4 4 6 Power Fail Input. PFI is the noninverting input to the power fail comparator. When PFI is less than 1.25 V, PFO goes low. If unused, PFI must be connected to GND. PFO 5 5 7 Power Fail Output. PFO is the output from the power fail comparator. It goes low when PFI is less than 1.25 V. WDI 6 Not applicable Not applicable Watchdog Input. WDI is a three-level input. If WDI remains either high or low for longer than the watchdog timeout period, the watchdog output (WDO) goes low. The timer resets with each transition at the WDI input. Either a high to low or a low to high transition clears the counter. The internal timer is also cleared whenever reset is asserted. The watchdog timer is disabled when WDI is left floating or connected to a three-state buffer. NC Not applicable 6 8 No Connect. RESET 7 7 1 Logic Output. RESET goes low for 200 ms when triggered. It can be triggered either by VCC being below the reset threshold or by a low signal on the manual reset input (MR). RESET remains low whenever VCC is below the reset threshold (4.65 V in ADM705/ADM707, 4.40 V in ADM706/ADM708). It remains low for 200 ms after VCC goes above the reset threshold or MR goes from low to high. A watchdog timeout does not trigger RESET unless WDO is connected to MR. WDO 8 Not applicable Not applicable Watchdog Output. WDO remains low until the watchdog timer is cleared. WDO also goes low during low line conditions. Whenever VCC is below the reset threshold, WDO goes low if the internal WDO remains low. As soon as VCC goes above the reset threshold, WDO goes high. RESET Not applicable 8 2 Logic Output. RESET is an active high output suitable for systems that use active high reset logic. It is the inverse of RESET. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |