3 / 4 page ![]() EOSD - Occupancy Sensor Sub Desk Installation Guide Copyright EnOcean © 2020 Page 3 of 4 EOSD_Installation_Guide_V2.1 Linking is the process by which different devices are configured to work with each other in a system. Sometimes this process is also called Teach-in or Learn-in. During Linking, the occupancy sensor has to communicate its unique device address and the profile that it uses to the receiver that will receive and react to telegrams from the sensor. This information is available either from the device label (QR code) or can be communicated via a dedicated telegram (a so- called teach-in telegram). To Link or Unlink an Occupancy Sensor 1. Set the desired receiver of the sensor telegram to Link or Unlink mode (refer to the receiver device’s installation guide). 2. Click the Menu button on the bottom of the sensor once. This sends a link/unlink radio telegram. NOTE: The button interface on the sensor is used for linking and testing only. The occupancy timer settings are configured on the transceiver to which the sensor is linked. Refer to the “Linking” section of the receiver installation guide to complete the linking & setup process. Use the walk test to confirm that motion is within the sensor’s range. NOTE: Before starting the test, ensure the battery is inserted for 5 minutes at least. If the sensor does not have a sufficient power, it cannot enter into the test mode. No LED light or 1 red blink when the set button is pressed indicates insufficient power. 1. Press and hold the Set button for 5 seconds. ••> Red LED will blink to confirm that a walk test is active. 2. Move in and out of the sensor‘s range to determine its coverage area. ••> Sensor will blink when it detects motion. 3. Make small hand movements just inside the limit of the sensor‘s range to see if the motion triggers a response. 4. The test mode will stay active for 3 minutes. To exit the test before and resume normal operation, press and hold the Menu button for 5 seconds. NOTE: Ensure the sensor does not falsely trigger from user activity outside the desired zone or other heat and motion sources. If false triggering occurs, adjust the sensitivity switch (next to the battery slot) from REG to LOW. Linking 3 Walk Test 4 |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |