| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
AS3682 Datasheet(PDF) 30 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3682 Datasheet(HTML) 30 Page - ams AG |
|
30 / 43 page ![]() AS3682 austriamicrosystems Data Sheet Charge Pump Control Registers www.austriamicrosystems.com Revision 2.21 30 - 43 11.5 Charge Pump Control Registers Addr: 00 Powerdown_control This register switches the charge pump and current sinks_1x on and off. Bit Bit Name Default Access Description 0 cp_led_on 0 R/W Charge pump enable/disable. 0 = Switches the charge pump off. 1 = Switches the charge pump on. 1 curr11_on See curr11_on (page 24). 2 curr12_on See curr12_on (page 24). 3 curr13_on See curr13_on (page 24). 7:4 N/A Addr: 0D CP_control This register sets the charge pump mode and reads the current charge pump mode. Bit Bit Name Default Access Description 0 cp_clk 0 R/W Charge pump clock frequency selection. 0 = 1MHz 1 = 500 kHz 1cp_man 0 R/W Charge pump mode control. 0 = Automatic mode. 1 = Manual mode. 3:2 cp_mode 00b R/W Charge pump mode selection. 01 = N/A 01 = Charge pump mode 1:1. 10 = Charge pump mode 1:1.5. 11 = Charge pump mode 1:2. 4 cp_mode2 0 R/W Used for test purposes only. 5:7 N/A Addr: 0F Curr_voltage_control This register indicates if the voltage at any current sink has dropped below a predefined value. If the charge pump is operating in automatic-mode (default), the contents of this register can be disregarded. The voltages at current sinks 1x are used for automatic mode selection of the charge pump. The voltages at current sinks 2, 3, and 4 can be optionally used for automatic mode selection of the charge pump (see register Curr234_ctrl (page 29)). Bit Bit Name Default Access Description 0 curr11_low_voltage N/A R See curr11_low_voltage (page 26). 1 curr12_low_voltage N/A R See curr12_low_voltage (page 26). 2 Curr13_low_voltage N/A R See curr13_low_voltage (page 26). 3 Curr2_low_voltage N/A R See Curr2_low_voltage (page 29). 4 Curr3_low_voltage N/A R See Curr3_low_voltage (page 29). 5 Curr4_low_voltage N/A R See Curr4_low_voltage (page 29). 7:6 cp_status N/A R 01 = Charge pump mode 1:1. 10 = Charge pump mode 1:1.5. 11 = Charge pump mode 1:2. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |