29 / 123 page ![]() ST20-GP6 29/123 4.6.5 Restrictions on trap handlers There are various restrictions that must be placed on trap handlers to ensure that they work cor- rectly. 1 Trap handlers must not deschedule or timeslice. Trap handlers alter the Enables masks, therefore they must not allow other processes to execute until they have completed. 2 Trap handlers must have their Enable masks set to mask all traps in their trap group to avoid the possibility of a trap handler trapping to itself. 3 Trap handlers must terminate via the tret (trap return) instruction. The only exception to this is that a scheduler kernel may use restart to return to a previously shadowed process. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|