| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
INA310B2 Datasheet(PDF) 22 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
INA310B2 Datasheet(HTML) 22 Page - Texas Instruments |
|
22 / 32 page ![]() 8.2.1.1 Design Requirements In this example application, the common-mode voltage ranges from 0 V to 24 V. The maximum sense current is 1.5 A, an alert must be indicated if the current exceeds 1.9 A, and a 5 V supply is available for the INA310x. Following the design guidelines from RSENSE and Device Gain Selection, a RSENSE of 50 mΩ and a gain of 50 V/V are selected to provide good output dynamic range. Table 8-2 lists the design setup for this application. Table 8-2. Design Parameters DESIGN PARAMETERS EXAMPLE VALUE Power supply voltage 5 V Common mode voltage range 0 V to 24 V Maximum sense current 1.5 A RSENSE resistor 50 mΩ Gain option 50 V/V Over-current Threshold 1.9 A R1 69.15 kΩ R2 10 kΩ 8.2.1.2 Detailed Design Procedure The INA310x is designed to measure current in a typical solenoid application. The INA310x measures current across the 50-mΩ shunt that is placed at the output of the half-bridge. The INA310x measures the differential voltage across the shunt resistor, and the signal is internally amplified with a gain of 50 V/V. The output of the INA310x is connected to the analog-to-digital converter (ADC) of an MCU to digitize the current measurements. R2 is fixed as 10 kΩ to avoid loading of OUT as recommended in Overcurrent Threshold Connection. R1 is calculated as 69.15 kΩ using Equation 1. 1.9A=0.6V×R1+10kΩ 10kΩ×50×50mΩ R1 (69.15 kΩ) and R2 (10 kΩ) divides down the output which is an input to the comparator. This sets the overcurrent alert threshold of 1.9 A. Solenoid loads are highly inductive and are often prone to failure. Solenoids are often used for position control, precise fluid control, and fluid regulation. Measuring real-time current on the solenoid continuously can indicate premature failure of the solenoid, which can lead to a faulty control loop in the system. Measuring high-side current also indicates if there are any ground faults on the solenoid or the FETs that can be damaged in an application. The INA310x, with high bandwidth and slew rate, can be used to detect fast overcurrent conditions to prevent the solenoid damage from short-to-ground faults. 8.2.1.2.1 Overload Recovery With Negative VSENSE The INA310x is a unidirectional current sense amplifier that is meant to operate with a positive differential input voltage (VSENSE). If negative VSENSE is applied, the device is placed in an overload or saturated condition and requires time to recover after VSENSE returns positive. The required overload recovery time increases with more negative VSENSE. INA310A, INA310B SBOSA86 – MARCH 2023 www.ti.com 22 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: INA310A INA310B |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |