| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ADM1177-2ARMZ-R7 Datasheet(PDF) 13 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1177-2ARMZ-R7 Datasheet(HTML) 13 Page - Analog Devices |
|
13 / 16 page ![]() Preliminary Technical Data ADM1177 Rev. PrD | Page 13 of 16 WRITE EXTENDED BYTE In this operation the master device writes to one of the three extended registers of the slave device, as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends the register address byte. The MSB of this byte is set to 1 to indicate an extended register write. The two LSBs indicate which of the three extended registers will be written to (see Table 7). All other bits should be set to 0. 5. The slave asserts ACK on SDA. 6. The master sends the command byte. The command byte is identified by an MSB = 0. (An MSB = 1 indicates an Extended Register Write. See next section.) 7. The slave asserts ACK on SDA. 8. The master asserts a STOP condition on SDA to end the transaction. S SLAVE ADDRESS RA A REGISTER ADDRESS P REGISTER DATA N 12 34 5 6 78 Figure 11. Command Byte Write Table 8, Table 9, and give details of each extended register. Table 7. Extended Register Addresses A6 A5 A4 A3 A2 A1 A0 Extended Register 0 0 0 0 0 0 1 ALERT_EN 0 0 0 0 0 1 0 ALERT_TH 0 0 0 0 0 1 1 CONTROL Table 8. ALERT_EN Register Operations Bit Default Name Function 0 0 EN_ADC_OC1 Enabled if a single ADC conversion on the I channel has exceeded the threshold set in the ALERT_TH register 1 0 EN_ADC_OC4 Enabled if four consecutive ADC conversions on the I channel have exceeded the threshold set in the ALERT_TH register 2 1 EN_HS_ALERT Enabled if the hotswap has either latched off, or entered a cool down cycle, because of an overcurrent event 3 0 EN_OFF_ALERT Enable an ALERT if the HS operation is turned off by a transition which de-asserts the ON pin, or by an operation which writes the SWOFF bit high. 4 0 CLEAR Clears the ON_ALERT, HS_ALERT and ADC_ALERT status bits in the STATUS register. These may immediately reset if the source of the alert has not been cleared, or disabled with the other bits in this register. This bit self-clears to 0 after the STATUS register bits have been cleared. Table 9. ALERT_TH Register Operations Bit Default Function 7:0 FF The ALERT_TH register sets the current level at which an alert will occur. Defaults to ADC full-scale. ALERT_TH 8-bit number corresponds to the top 8-bits of the current channel data. Table 10. CONTROL Register Operations Bit Default Name Function 0 0 SWOFF Force hotswap off. Equivalent to de-asserting the ON pin. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |