Back Button TLVM14404 Datasheet HTML 22Page - Texas Instruments TLVM14404 Datasheet HTML 23Page - Texas Instruments TLVM14404 Datasheet HTML 24Page - Texas Instruments TLVM14404 Datasheet HTML 25Page - Texas Instruments TLVM14404 Datasheet HTML 26Page - Texas Instruments TLVM14404 Datasheet HTML 27Page - Texas Instruments TLVM14404 Datasheet HTML 28Page - Texas Instruments TLVM14404 Datasheet HTML 29Page - Texas Instruments TLVM14404 Datasheet HTML 30Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 26 / 46 page
background image
7.3.11 Thermal Shutdown
Thermal shutdown is an integrated self-protection used to limit junction temperature and prevent damage related
to overheating. Thermal shutdown turns off the device when the junction temperature exceeds 168°C (typical) to
prevent further power dissipation and temperature rise. Junction temperature decreases after shutdown, and the
TLVM1440x attempts to restart when the junction temperature falls to 159°C (typical).
7.4 Device Functional Modes
7.4.1 Shutdown Mode
The EN pin provides ON and OFF control for the TLVM1440x. When VEN is below approximately 0.4V, the
device is in shutdown mode. Both the internal LDO and the switching regulator are off. The quiescent current in
shutdown mode drops to 0.6µA (typical). The TLVM1440x also employs internal undervoltage protection. If the
input voltage is below the UV threshold, the regulator remains off.
7.4.2 Standby Mode
The internal LDO for the VCC bias supply has a lower enable threshold than the regulator. When VEN is above
1.1V (maximum) and below the precision enable threshold of 1.263V (typical), the internal LDO is on and
regulating. The precision enable circuitry is turned on after the internal VCC is above the UVLO threshold. The
switching action and voltage regulation are not enabled until VEN rises above the precision enable threshold.
7.4.3 Active Mode
The TLVM1440x is in active mode when VVCC and VEN are above the relevant thresholds and no fault conditions
are present. The simplest method to enable operation is to connect EN to VIN, which allows self start-up when
the applied input voltage exceeds the minimum start-up voltage.
TLVM14404, TLVM14406
SLVSHP0 – JULY 2024
www.ti.com
26
Submit Document Feedback
Copyright © 2024 Texas Instruments Incorporated
Product Folder Links: TLVM14404 TLVM14406



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com