45 / 68 page ![]() Advanced Overload Education Description Definition Source Result Motor Insight Protection Motor Protection Thermal overload Overload is a condition in which current draw to a motor exceeds 115% of the full load amperage rating over a period of time for an inductive motor. An increase in the load or torque that is being driven by the motor. A low voltage supply to the motor would cause the current to go high to maintain the power needed. A poor power factor would cause above normal current draw. Increase in current draw. Current leads to heat and insulation breakdown, which can cause system failure. Additionally, an increase in current can increase power consumption and waste valuable energy. Thermal trip behavior is defined by UL, CSA and IEC standards. Trip class is settable from 5–30 by 1 Provides power factor monitoring and low voltage protection features. Jam Jam is similar to thermal overload in that it is a current draw on the motor above normal operating conditions. Mechanical stall, interference, jam or seizure of the motor or motor load. The motor attempts to drive the load, which has more resistive force due to the mechanical interference. In order to drive the load, the motor draws an abnormal amount of current, which can lead to insulation breakdown and system failure. Provides a configurable Jam setting that is active during “motor run state” to avoid nuisance trips. Trip Threshold 150–400% of FLA. Trip Delay 1–20 seconds. Ground fault A line to ground fault. A current leakage path to ground. An undetected ground fault can burn through multiple insulation windings, ultimately leading to motor failure. Motor Insight has ground fault protection capability down to 0.15 amps estimated from the existing three-phase CTs using the residual current method. That is, the three-phase current signals should sum to zero unless a ground fault (GF) condition is present. In the case of a GF, Motor Insight can alarm, trip the starter, or trip an alternative relay that can be used to shunt trip a breaker or light up a warning light. GF current can also be monitored in real-time through the advanced monitoring capabilities. Note: GF settable thresholds vary with motor FLA. 0.15 amps may not be available in all cases. Imbalanced phases (voltage and current) Uneven voltage or currents between phases in a three-phase system. When a three-phase load is powered with a poor quality line, the voltage per phase may be imbalanced. Imbalanced voltage causes large imbalanced currents and as a result this can lead to motor stator windings being overloaded, causing excessive heating, reduced motor efficiency and reduced insulation life. Provides two protection settings that address this problem. The user can choose to set current imbalance thresholds or voltage imbalance thresholds, each of which can trip the starter. Additionally, both of these may be monitored through Motor Insight’s advanced monitoring capabilities, allowing the customer to notice in real- time when and where a condition is present. Phase loss—current (single-phasing) One of the three-phase current is not present. Multiple causes, loose wire, improper wiring, grounded phase, open fuse, and so on. Single-phasing can lead to unwanted motor vibrations in addition to the results of imbalanced phases as listed above. Fixed protective setting that takes the starter offline if a phase drops below 60% of the other two phases. Phase rotation (phase-reversal) Improper wiring, leading to phases being connected to the motor improperly. A miswired motor. Inadvertent phase- reversal by the utility. Phase-reversal can cause unwanted directional rotation of a motor. In the event that the load attached to the motor can only be driven in one direction, the result could be significant mechanical failure and/or injury to an operator. Configurable phase protection, allowing the user to define the phase sequencing intended for that application. If no phase sequence is required, the user has the ability to disable this feature. Frequency variance When line frequency is inconsistent. Malfunctioning alternator speed regulator, or poor line quality caused by an overload of a supply powered by individual sources. Variations in frequency can cause increases in losses, decreasing the efficiency of the motor. In addition, this can result in interference with synchronous devices. Advanced monitoring capabilities allow the user to monitor frequency in real-time. C441 Overload and monitoring relay Features and benefits AUTOMATION AND CONTROL www.eaton.com/seasia-electrical 46 1 1 1.2 |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |