| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
CSG14K_CSG8K Datasheet(PDF) 102 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
CSG14K_CSG8K Datasheet(HTML) 102 Page - OSRAM GmbH |
|
102 / 114 page ![]() Document Feedback CSG14K_CSG8K Functional Description Datasheet • PUBLIC DS000571 • v2-01 • 2023-Feb-10 113 │ 101 Calibration of the temperature sensor readout value involves two steps: 1. Calculate the calibration gain coefficient using following equation: Equation 18: ������������������������ = ������������������������������������,������������������������������������������������[°������] + 273.15 ������������������������������������,������������������������������������������������[°������] + 273.15 Which uses following parameters: ● Twafer,expected is the expected temperature at wafer test, which is close to 60 ⁰C. The exact value is stored in OTP register “Chuck Temperature” (see Figure 126). ● Twafer,measured is the measured (uncalibrated) temperature sensor value at wafer test. The values can be calculated based on the temperature sensor readout values TSENS_REF and TSENS_CONV , as stored in OTP registers “TSENSx_CONV” and “TSENSx_REF” (see Figure 126). Using both values, the corresponding temperature value can be calculated using Equation 19. This calibration gain coefficient is fixed and only needs to be calculated once. Note that a separate calibration gain coefficient needs to be calculated for both temperature sensors. 2. Calculate the calibrated temperature measurement value using following equation: Equation 19: ������������������������ [°������] = ������������������������ × (������������������������������������,������[°������] + 273.15) − 273.15 7.8.7 Enable Optical Black Outputs The OB pixels on the right side of the pixel array that are used for on-chip OB correction can be read out through the DOUT_OB_* output channels. By default, these channels are disabled. To enable the DOUT_OB_* channels, use the SPI sequence listed in Figure 129. Note that the registers should only be written to the specified BLOCK_IDs. Figure 129: Enable OB Outputs Sequence # Register Bank Address BLOCK_ID Value 1 DATA_CH_CTRL 3 74 18 1027 2 DATA_CH_CTRL 3 74 19 1027 Using the DOUT_OB_* channels is optional. Using the channels requires routing additional output channels to the receiving system. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |