| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
SLCU6LL Datasheet(PDF) 3 Page - Europa PLC |
|
|
|||||||||||||||||||||||||||||
SLCU6LL Datasheet(HTML) 3 Page - Europa PLC |
|
3 / 4 page ![]() Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS1392-004 Page 3 of 4 EUR PA Unit Characteristics Rated and operational voltage (Un / Ue) 230V AC at 50Hz Rated impulse withstand voltage (Uimp) 4kV Rated current of Assembly (lnA) 100A, 63A, 40A Rated frequency (fn) 50Hz Degree of Protection IP20 Mechanical Impact Protection IK05 Note: Rated diversity factor (RDF) only applies to continuously and simultaneously loaded circuits. Type A Distribution Board for use by ordinary persons. Device Standard Consumer Unit BS EN 61439-3 / EN 61439-3 Main Switch BS EN 60947-3 / EN 60947-3 RCCB BS EN 61008-1 / EN 61008-1 MCB BS EN 60898-1 / EN 60898-1 RCBO BS EN 61009-1 / EN 61009-1 Number of Outgoing Ways Assumed loading factor 2 & 3 0.8 4 & 5 0.7 6 to 9 0.6 10+ 0.5 Device Max Cable Capacity (mm2) Recommended Tightening Torque (Nm) Main Switch / RCCBs 35 2.5 MCBs 16 2.0 1 Pole RCBO 16 In 2.0 | Out 1.2 Earth and Neutral Terminals 25 2.0 Cable and Torque Settings Diversity Factors as per BS EN 61439-3 Standards ENSURE THAT THESE INSTRUCTIONS ARE MADE AVAILABLE TO THE END USER FOR FUTURE REFERENCE WARNING! ALL CONNECTIONS, INCLUDING FACTORY- MADE, MUST BE CHECKED FOR THE CORRECT INSTALLATION AND TIGHTNESS, PRIOR TO THE COMMISSIONING OF THE ELECTRICAL INSTALLATION. Widest pin to be installed in the main switch or an RCCB feeding MCBs End cap Raised lip for finger protection Fitting the Busbar Fully open the terminals and insert the busbar within the clamp correctly. Ensure that the widest pin is inserted to the main switch or the RCCB which is feeding the downstream MCBs. The busbar cover provided has a raised lip on one side which provides finger protection when the busbar is installed. Ensure that this lip is facing up when installing the busbar. Ensure the end caps provided are used to fully cover the busbar when installed. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |