Motor de Búsqueda de Datasheet de Componentes Electrónicos
  Mexican  ▼
ALLDATASHEET.COM.MX

X  

DPM970 Datasheet(PDF) 2 Page - Lascar Electronics

No. de pieza DPM970
Descripción Electrónicos  Digital AC Voltmeter Module
PDF  2 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrónico  LASCAR [Lascar Electronics]
Página de inicio  lascarelectronics.com
Logo LASCAR - Lascar Electronics

DPM970 Datasheet(HTML) 2 Page - Lascar Electronics

  DPM970 Datasheet HTML 1Page - Lascar Electronics DPM970 Datasheet HTML 2Page - Lascar Electronics  
Zoom Inzoom in Zoom Outzoom out
 2 / 2 page
background image
APPLICATIONS
WARNING : Do not apply in excess of 500V a.c. to the meter.
3-Phase Current and Voltage
Measurement
Load
PSU 303
Phase 3
Neutral
V-
V-
V+
110/240V
+5V
V+
COM
COM
ACI
ACV
Load
PSU 303
Phase 1
V-
V-
V+
110/240V
+5V
0V
-5V
0V
-5V
0V
-5V
V+
COM
COM
ACI
ACV
Voltage
Current
Voltage
Current
Voltage
Current
Load
PSU 303
Phase 2
V-
V-
V+
110/240V
+5V
V+
COM
COM
ACI
ACV
Voltage
Current
Single Phase Current and Voltage
Measurement
Load
PSU 303
Phase
Neutral
V-
V-
V+
V-
V+
0V
110/240V
+5V
-5V
V+
COM
COM
ACI
ACV
Using a current transformer (CT) to
measure currents in excess of 10A a.c.
0V
V-
V+
Load
Phase
Neutral
COM
ACI
CT
PSU 303
110/240V
+5V
-5V
Powering the LED backlighting on a DPM 970
from the PSU 303's +5V and COM outputs.
0V
LP-
LP+
Phase
Neutral
PSU 303
110/240V
+5V
-5V
COM
SCREW TERMINAL FUNCTIONS
ACV
Alternating voltage measurement input, accepts up to 500V a.c. By changing the values of scaling resistors RA1, RA2 and RB1, other voltage and
current ranges can be achieved. To measure in excess of 500V a.c., remove RA1, RA2 and RB1 from the meter and fit an external divider that will output
700mV for a 2kV input, e.g. series resistor 1.12 M shunt resistor 390R, link RA1 and RA2 on the meter. See scaling table for suitable values for RA1,
RA2 and RB1.
ACI
Alternating current measurement input.
See Scaling table for suitable values for shunt resistor RB1.
COM
Return line for voltage measurement input (ACV) or current measurement (ACI) input.
COM
W
Return line for voltage measurement input (ACV) or current measurement (ACI) input.
V+
Positive power supply input.
V-
Negative power supply input.
LP-
Negative supply for LED backlighting.
LP+
Positive supply for LED backlighting.
TST
Connect to V+ to display all segments except decimal points and annunciators.
It should not be operated for more than a few seconds as the DC voltage applied
to the LCD may “burn” the display. This connection is normally at 5V below V+
and is the ground for the digital section of the meter.
HLD
Digital Hold option. Connect to V+ to hold last displayed reading indefinitely.
ALM
Alarm “!” annunciator. Connect to XDP to display.
XDP
Annunciator drive waveform. Used to drive alarm annunciator (ALM) if required.
V+
Auxilliary V+ for connections to decimal points DP1, DP2 or DP3.
DP1
199.9
Connect to V+ to display required decimal point.
DP2
19.99
Connect to V+ to display required decimal point.
DP3
1.999
Connect to V+ to display required decimal point.
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s connectors must not exceed 500VRMS. If voltages to be measured exceed
500VRMS, then fit scaling resistors externally to the module. If the mains power supply is connected to the module, then all the module’s connectors must be
considered to be floating at mains potential. Consequently due caution must be exercised when connecting to the module’s connector functions under these
conditions. The user must ensure that the incorporation of the DPM into the user’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements
for Electrical Equipment for Measuring, Control and Laboratory Use).
SAFETY WARNING
LASCAR ELECTRONICS LTD.
MODULE HOUSE, WHITEPARISH,
WILTSHIRE SP5 2SJ
UK
TEL: +44 (0)1794 884567 FAX: +44 (0)1794 884616
E-mail: sales@lascar.co.uk
Specifications liable to change without prior warning
DPM 970
Issue 12
06/2010
S.L.
Applies to DPM 970/12
LASCAR ELECTRONICS INC.
4258 WEST 12th STREET,
ERIE, PA 16505 USA
TEL: +1 (814) 835 0621 FAX: +1 (814) 838 8141
E-mail: us-sales@lascarelectronics.com
LASCAR ELECTRONICS (HK) LTD.
8th FLOOR, CHINA AEROSPACE CENTRE, 143 HOI BUN
ROAD, KWUN TONG, KOWLOON, HONG KONG
TEL: +852 2389 6502 FAX: +852 2389 6535
E-mail: saleshk@lascar.com.hk
1
1
1
1



Html Pages

1 2


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com