  K100PLNZRGB7A Datasheet HTML 1Page - Banner Engineering Corp. K100PLNZRGB7A Datasheet HTML 2Page - Banner Engineering Corp. K100PLNZRGB7A Datasheet HTML 3Page - Banner Engineering Corp. K100PLNZRGB7A Datasheet HTML 4Page - Banner Engineering Corp. K100PLNZRGB7A Datasheet HTML 5Page - Banner Engineering Corp. K100PLNZRGB7A Datasheet HTML 6Page - Banner Engineering Corp.  
Zoom Inzoom in Zoom Outzoom out
 2 / 6 page
background image
 
June 12, 2023
page 2
(1) Aggressive substances—for example, acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials.
(2) Suitable precaution—for example, regular checks as part of routine inspections or establishing from the materials data sheet that is resistant to specific chemi­
cals.
K100 Pro Hazardous Indicator Beacon - AC Datasheet
◦
◦
◦
◦
•
•
•
•
•
•
◦
◦
All installations must comply with all manufacturer's instructions.
All applicable wiring methods in accordance with the relevant local regulations and the authority having jurisdiction.
U.S. Installations: The relevant requirements of the National Electric Code® (ANSI/NFPA­70 NEC®).
Canadian Installations: The relevant requirements of the Canadian Electrical Code (CSA C22.1).
Do not attempt any repairs to this device; it contains no field-replaceable parts or components. Tampering and/or replacement with
non-factory components may adversely affect the safe use of the system.
The nonconducting materials of this device may be susceptible to ignition-capable level of electrostatic charging and precautions
must be taken to avoid this. The user/installer shall ensure that the equipment is not installed in a location where it may be subjected 
to external conditions (such as high-pressure steam) which are conducive to creating a build-up of electrostatic charges.
Clean with a damp cloth only.
If the equipment is likely to come into contact with aggressive substances(1), then it is the responsibility of the user to take suitable
precautions(2) that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised.
The ingress protection (IP rating) of enclosures/panels may be invalidated by the installation of the beacon. The installation of the
beacon in a particular enclosure/panel is subject to the evaluation/acceptance of the authority having jurisdiction.
Models with integral quick-disconnect (QD) connectors:
Use recommended Banner cordsets (see "Cordsets" on page 4), or suitable quick­disconnect cordsets with threaded retain­
ing nut (see "Specifications" on page 3). The cordset must be securely fastened using the quick­disconnect retaining nut to 
prevent disconnection. Maximum connector torque: 6 ft-lbs.
Must be installed such that the connector is protected from impact and unauthorized disconnection. The method of protec­
tion can include conduit (e.g. pole, pendent), enclosed raceway, a listed enclosure suitable for the intended use, and/or by 
inaccessible location that excludes possible impact damage.
Wiring
Diagram
Key
2
3
1
A
3
4
1
2
5
Neutral
Hot
1 = Brown 
2 = Blue 
3 = White 
4 = Black 
5 = Gray 
An "X" denotes an active input. 
For example: When the black wire and the white wire are both active, the indicator will be Magenta Steady. 
Default Configuration
Wiring 
Operating Mode/Function 
Brown 
Blue 
Black 
Gray 
Non­Audible 
Audible 
 X 
 
 
 
 Red Steady 
 Red Steady 
 
 X 
 
 
 Green Steady 
 Green Steady 
 
 
 X 
 
 Blue Steady 
 Blue Steady 
 X 
 X 
 
 
 Yellow Steady 
 Yellow Steady 
 X 
 
 X 
 
 Magenta Steady 
 Magenta Steady 
 
 X 
 X 
 
 Cyan Steady 
 Cyan Steady 
 X 
 X 
 X 
 
 White Steady 
 White Steady 
 
 
 
 X 
 Off 
 Audible Steady, Frequency 2.5 KHz, Volume High 
 X 
 
 
 X 
 Red Steady 
 Red Steady, Audible Steady, Frequency 2.5 KHz, Volume High 
 
 X 
 
 X 
 Green Steady 
 Green Steady, Audible Steady, Frequency 2.5 KHz, Volume High 
 
 
 X 
 X 
 Blue Steady 
 Blue Steady, Audible Steady, Frequency 2.5 KHz, Volume High 
 X 
 X 
 
 X 
 Yellow Steady 
 Yellow Steady, Audible Steady, Frequency 2.5 KHz, Volume High 
 X 
 
 X 
 X 
 Magenta Steady 
 Magenta Steady, Audible Steady, Frequency 2.5 KHz, Volume High 
Continued on page 3
© Banner Engineering Corp.



Html Pages

1 2 3 4 5 6


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com