Back Button C/NEW DATA Datasheet HTML 2Page - TEKTRONIX, INC C/NEW DATA Datasheet HTML 3Page - TEKTRONIX, INC C/NEW DATA Datasheet HTML 4Page - TEKTRONIX, INC C/NEW DATA Datasheet HTML 5Page - TEKTRONIX, INC C/NEW DATA Datasheet HTML 6Page - TEKTRONIX, INC C/NEW DATA Datasheet HTML 7Page - TEKTRONIX, INC C/NEW DATA Datasheet HTML 8Page - TEKTRONIX, INC C/NEW DATA Datasheet HTML 9Page - TEKTRONIX, INC C/NEW DATA Datasheet HTML 10Page - TEKTRONIX, INC Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 16 page
background image
Datasheet
TEK.COM
6
TriggerFlow® Building Blocks for
Instrument Control and Execution
The 2461 incorporates Keithley’s TriggerFlow triggering
system, which provides user control over instrument
execution. TriggerFlow diagrams are created in much
the same way that flow charts are developed, using four
fundamental building block types::
• Wait – Waits for an event to occur before the
flow continues
• Branch – Branches when a condition has
been satisfied
• Action – Initiates an action in the instrument, for
example, measure, source, delay, set digital I/O, etc.
• Notify – Notifies other equipment that an event
has occurred
TriggerFlow building blocks allow creating triggering models that range
from very simple to highly complex.
A TriggerFlow model using a combination of these building
blocks can be created from the front panel or by sending
remote commands. With the TriggerFlow system, users
can build triggering models from very simple to complex
with up to 63 block levels. The 2461 also includes basic
triggering functions, including immediate, timer, and
manual triggering.
Contact Check Function
The Contact Check function makes it simple to verify
good connections quickly and easily before an automated
test sequence begins. This eliminates measurement
errors and false failures associated with contact fatigue,
breakage, contamination, loose or broken connection,
relay failures, etc. Some capabilities of this function are:
• <100 μs verification and notification process time
• 3 pass/fail threshold values: 2 Ω, 15 Ω, and 50 Ω
• Enabled remotely over the GPIB, USB, or Ethernet
(LXI) interfaces
Unmatched System Integration and
Programming Flexibility
When a 2461 is configured into a multi-channel I-V test
system, its embedded Test Script Processor (TSP®)
allows it to run test scripts, so users can create powerful
measurement applications with significantly reduced
development times. TSP technology also offers channel
expansion without a mainframe. Keithley’s TSP-Link®
channel expansion bus, which uses a 100 Base T Ethernet
cable, can connect multiple graphical SourceMeter SMUs
(2450, 2460, 2461), and other TSP instruments such
as Keithley’s DMM7510 7½-Digit Graphical Sampling
Multimeter, Series 2600B System SourceMeter SMU
instruments, and Series 3700A Switch/Multimeter systems
in a master-subordinate configuration that operates
as one integrated system. The TSP-Link expansion
bus supports up to 32 units per GPIB or IP address,
making it easy to scale a system to fit an application’s
particular requirements. The 2461 also includes a SCPI
programming mode that takes advantage of all of the
instrument’s capabilities.
Parallel Test Capability
The TSP technology in the 2461 supports testing multiple
devices in parallel to meet the needs of device research,
advanced semiconductor lab applications, and even high
throughput production test. This parallel testing capability
allows each instrument in the system to run its own
complete test sequence, creating a fully multi-threaded
test environment. The number of tests that can be run in
parallel on a graphical SourceMeter can be as high as the
number of instruments in the system.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com