| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
M29DW324DB Datasheet(PDF) 15 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M29DW324DB Datasheet(HTML) 15 Page - STMicroelectronics |
|
15 / 49 page ![]() 15/49 M29DW324DT, M29DW324DB COMMAND INTERFACE All Bus Write operations to the memory are inter- preted by the Command Interface. Commands consist of one or more sequential Bus Write oper- ations. Failure to observe a valid sequence of Bus Write operations will result in the memory return- ing to Read mode. The long command sequences are imposed to maximize data security. The address used for the commands changes de- pending on whether the memory is in 16-bit or 8- bit mode. See either Table 5, or 6, depending on the configuration that is being used, for a summary of the commands. Read/Reset Command The Read/Reset command returns the memory to its Read mode where it behaves like a ROM or EPROM. It also resets the errors in the Status Register. Either one or three Bus Write operations can be used to issue the Read/Reset command. The Read/Reset command can be issued, be- tween Bus Write cycles before the start of a pro- gram or erase operation, to return the device to read mode. If the Read/Reset command is issued during the timeout of a Block erase operation then the memory will take up to 10µs to abort. During the abort period no valid data can be read from the memory. The Read/Reset command will not abort an Erase operation when issued while in Erase Suspend. Auto Select Command The Auto Select command is used to read the Manufacturer Code, the Device Code, the Block Protection Status and the Extended Memory Block Verify Code. It can be addressed to either Bank. Three consecutive Bus Write operations are re- quired to issue the Auto Select command. The fi- nal Write cycle must be addressed to one of the Banks. Once the Auto Select command is issued Bus Read operations to the Bank where the com- mand was issued output the Auto Select data. Bus Read operations to the other Bank will output the contents of the memory array. The memory re- mains in Auto Select mode until a Read/Reset or CFI Query command is issued. In Auto Select mode the Manufacturer Code can be read using a Bus Read operation with A0 = VIL and A1 = VIL and A20 = Bank Address. The other address bits may be set to either VIL or VIH. The Device Code can be read using a Bus Read operation with A0 = VIH and A1 = VIL and A20 = Bank Address. The other address bits may be set to either VIL or VIH. The Block Protection Status of each block can be read using a Bus Read operation with A0 = VIL, A1 = VIH, A20 = Bank Address and A12-A17 spec- ifying the address of the block inside the Bank. The other address bits may be set to either VIL or VIH. If the addressed block is protected then 01h is output on Data Inputs/Outputs DQ0-DQ7, other- wise 00h is output. Read CFI Query Command The Read CFI Query Command is used to read data from the Common Flash Interface (CFI) Memory Area. This command is valid when the de- vice is in the Read Array mode, or when the device is in Autoselected mode. One Bus Write cycle is required to issue the Read CFI Query Command. Once the command is is- sued subsequent Bus Read operations read from the Common Flash Interface Memory Area. The Read/Reset command must be issued to re- turn the device to the previous mode (the Read Ar- ray mode or Autoselected mode). A second Read/ Reset command would be needed if the device is to be put in the Read Array mode from Autoselect- ed mode. See Appendix B, Tables 23, 24, 25, 26, 27 and 28 for details on the information contained in the Common Flash Interface (CFI) memory area. Program Command The Program command can be used to program a value to one address in the memory array at a time. The command requires four Bus Write oper- ations, the final write operation latches the ad- dress and data, and starts the Program/Erase Controller. If the address falls in a protected block then the Program command is ignored, the data remains unchanged. The Status Register is never read and no error condition is given. During the program operation the memory will ig- nore all commands. It is not possible to issue any command to abort or pause the operation. After programming has started, Bus Read operations in the Bank being programmed output the Status Register content, while Bus Read operations to the other Bank output the contents of the memory array. See the section on the Status Register for more details. Typical program times are given in Table 7. After the program operation has completed the memory will return to the Read mode, unless an error has occurred. When an error occurs Bus Read operations to the Bank where the command was issued will continue to output the Status Reg- ister. A Read/Reset command must be issued to reset the error condition and return to Read mode. Note that the Program command cannot change a bit set at ’0’ back to ’1’. One of the Erase Com- mands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |