| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
OPS2 Datasheet(PDF) 17 Page - ABB |
|
|
|||||||||||||||||||||||||||||
OPS2 Datasheet(HTML) 17 Page - ABB |
|
17 / 192 page ![]() — Manual switch-disconnectors OT16...100, UL Technical data for non fusible disconnect switches Technical data according to IEC 60947-3 Switch type OT16F OT25F OT40F OT63F OT80F OT30F OT60F OT100F Rated insulation voltage and rated operational voltage AC20/DC20 Pollution degree 3 750 V 750 V 750 V 750 V 750 V 750 V 750 V 750 V Dielectric strength 50 Hz 1 min. 6 kV 6 kV 6 kV 6 kV 6 kV 6 kV 6 kV 6 kV Rated impulse withstand voltage 8 kV 8 kV 8 kV 8 kV 8 kV 8 kV 8 kV 8 kV Rated operational current, AC-22A up to 415 V 16 A 25 A 40 A 63 A 80 A 40 A 63 A 100 A 440...500 V 16 A 25 A 40 A 63 A 80 A 40 A 63 A 100 A 690 V 16 A 25 A 40 A 63 A 80 A 40 A 63 A 100 A Rated operational current, AC-23A up to 415 V 16 A 20 A 23 A 63 A 75 A 40 A 63 A 80 A 440 V 16 A 20 A 23 A 63 A 65 A 40 A 63 A 65 A 500 V 16 A 20 A 23 A 45 A 58 A 40 A 63 A 60 A 690 V 10 A 11 A 12 A 20 A 20 A 40 A 40 A 40 A Rated conditional short- circuit current Iq (r.m.s.) and corresponding max. Allowed cut-off current Îc of fuse. The cut-off current Îc referes to values listed by fuse manufacturers (single phase test acc. To IEC60269) Iq 50kA, 415V Max. OFA_ fuse size Îc 6.5 kA 6.5 kA 6.5 kA 13 kA 13 kA 16.5 kA 16.5 kA 16.5 kA gG/aM 40 A/32 A 40 A/3 2A 40 A/32 A 100 A/80 A 100 A/80 A 125 A/125 A 125 A/125 A 125 A/125 A Iq 10kA, 690V Max. OFA_ fuse size Îc – – – – – 8.2 kA 8.2 kA 8.2 kA gG/aM – – – – – 125 A/100 A 125 A/100 A 125 A/100 A Iq 50kA, 690V Max. OFA_ fuse size Îc 4 kA 4 kA 4 kA 11 kA 11 kA 10 kA 10 kA 10 kA gG/aM 25 A/16 A 25 A/16 A 25 A/16 A 80 A/63 A 80 A/63 A 63 A/63 A 63 A/63 A 63 A/63 A Rated short-time withstand current r.m.s. -value Icw 690 V, 1 s 0.5 kA 0.5 kA 0.5 kA 1 kA 1.5 kA 2.5 kA 2.5 kA 2.5 kA Rated short circuit making capacity Peak value Icm 690 V/500 V 0.71 kA 0.71 kA 0.71 kA 1.4 kA 2.1 kA 3.6 kA 3.6 kA 3.6 kA Power loss / pole At rated operational current 0.3 W 0.6 W 1.6 W 2.8 W 4.5 W 0.7 W 1.6 W 4.0 W Mechanical endurance Divide by two for operation cycles 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper. Weight without accessories 3-pole 0.11 kg 0.11 kg 0.11 kg 0.27 kg 0.27 kg 0.36 kg 0.36 kg 0.36 kg 4-pole 0.15 kg 0.15 kg 0.15 kg 0.35 kg 0.35 kg 0.50 kg 0.50 kg 0.50 kg ABB SWITCH-DISCONNECTORS – HIGH PERFORMANCE, COMPACT SOLUTION 17 ABB SWITCH-DISCONNECTORS – HIGH PERFORMANCE, COMPACT SOLUTION 17 |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |