| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
OPS2EN1 Datasheet(PDF) 18 Page - ABB |
|
|
|||||||||||||||||||||||||||||
OPS2EN1 Datasheet(HTML) 18 Page - ABB |
|
18 / 192 page ![]() — Manual switch-disconnectors OT160G_, IEC and UL Technical data for non fusible disconnect switches Technical data according to UL98, CSA C22.2 No.4 c ULus Listed UL Recognized General purpose amp rating max. operating voltage pf=0.7…0.8 -40° to 40 °C 100 A 125 A 600 V 600 V Max. horsepower rating/motor FLA current pf=0.4…0.5 240 Vac 40 HP/104 A 40 HP/104 A Three phase 480 Vac 75 HP/96 A 75 HP/96 A 600 Vac 100 HP/99 A 100 HP/99 A Single phase 240 Vac 20 HP/88 A 20 HP/88 A 480 Vac 30 HP/66 A 30 HP/66 A 250 Vdc 20 HP/60 A 20 HP/60 A Fuse size/short circuit rating Fuse type J 150 A/100 kA 150 A/100 kA T 150 A/100 kA 150 A/100 kA RK5 60 A/100 kA 60 A/100 kA Endurances Min. electrical endurance, pf. 0.75 - 0.8 6 000 Oper. cycles 6 000 Oper. cycles Mechanical endurance 20 000 Operations 20 000 Operations Terminal lug kits integrated integrated Wire range Use copper conductors only 60-75 °C 8-1/0 AWG 8-1/0 AWG Torque Wire tightening 53 lb.in 53 lb.in Weight without accessories 3-pole switch 0.5 lb 0.5 lb 4-pole switch 0.6 lb 0.6 lb Minimum enclosure dimensions Height x width x depth 400 x 600 x 230 mm – 15.75 x 23.62 x 9.06 in – Technical data according to IEC 60947 Rated insulation voltage Pollution degree 3 1 000 V Dielectric strength 50 Hz 1 min. 10 kV Rated impulse withstand voltage 12 kV Rated thermal current in ambient 35 °C and temporarily 40 °C In open air 160 A In enclosure 160 A ...with minimum cable or bar cross section Cu 70 mm² Rated operational voltage AC-20 and DC-20 1 000 V Rated operational current, AC-21A, AC-22A, AC-23A up to 415 V 160 A 500 V 160 A 690 V 160 A Rated operational current / poles in series for DC-21A, DC-22A, DC23A Up to 220 V 160 A/2 440 V 125 A/3 680 V 125 A/4 Rated operational power, AC-23 The kW-ratings are accurate for three-phase 1500 R.P.M. standard asynchronous motors. 230 V 45 kW 400 V 75 kW 415 V 75 kW 500 V 90 kW 690 V 132 kW Rated breaking capacity in category AC-23 up to 500 V 1 280 690 V 1 280 Rated conditional short-circuit current Iq (r.m.s.) and corresponding max. Allowed cut-off current Îc of fuse. The cut-off current Îc referes to values listed by fuse manufacturers (single phase test acc. To IEC60269) Iq 100kA, 500V Max. OFA_fuse size Îc 30 kA gG/aM 200 A/200 A Iq 100kA, 690V Max. fuse size Îc 24 kA gG/aM -/200A Rated short-time withstand current R.M.S.-value Icw 690 V 0.25 s 7 kA 690 V 1 s 4 kA Rated short-circuit making capacity Peak value Icm 690 V 12 kA Rated capacitor power when no initial charge on the capacitor Capacitor ratings limited by fuse links 415 V 65 kVAr Power loss / pole With rated current 6.5 W Mechanical endurance Divide by two for operation cycles 20 000 Oper. Weight without accessories 3-pole switch 1.1 kg/0.5 lb 4-pole switch 1.3 kg/0.6 lb Standard shaft and mounting depth Square dimension x length of shaft 6X210 mm Corresponding mounting depth 230-248 mm/9.2-9.9 in Standard handle OHB65J6 Type Cu-wire size suitable for terminal 60-75 °C 10-70 mm²/ 8-1/0 AWG Terminal tightening torque 6 Nm/53 lb·in Operating torque Typical for 3 and 4-pole switches 4 Nm/35.3 lb·in 18 ABB SWITCH-DISCONNECTORS – HIGH PERFORMANCE, COMPACT SOLUTION 18 ABB SWITCH-DISCONNECTORS – HIGH PERFORMANCE, COMPACT SOLUTION |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |