Back Button PTPLD1202DYYR Datasheet HTML 45Page - Texas Instruments PTPLD1202DYYR Datasheet HTML 46Page - Texas Instruments PTPLD1202DYYR Datasheet HTML 47Page - Texas Instruments PTPLD1202DYYR Datasheet HTML 48Page - Texas Instruments PTPLD1202DYYR Datasheet HTML 49Page - Texas Instruments PTPLD1202DYYR Datasheet HTML 50Page - Texas Instruments PTPLD1202DYYR Datasheet HTML 51Page - Texas Instruments PTPLD1202DYYR Datasheet HTML 52Page - Texas Instruments PTPLD1202DYYR Datasheet HTML 53Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 49 / 192 page
background image
7.3.4.3.2 Reset Counter Mode
When configured as a Counter (CNT) and a valid edge appears on the IN input, this macro-cells resets the
internal counter to 0 and begins counting down from DATA on the next rising clock edge. Then, the macro-cell
outputs a pulse for the duration of one CLK period when the count reaches 0 and wrap around to the value in
DATA. The counter continually operates until another reset is received. The edge on which the Counter is reset
is determined by the Edge select parameter and can be configured as:
• Rising: only rising edges of IN reset the counter.
• Falling: only falling edges of IN reset the counter.
• Both: both rising and falling edges of IN reset the counter.
• High Level Reset: the counter is reset to 0 whenever IN is High; after reset, the counter output stays Low until
the next rising CLK edge, then operates normally.
The counter time is calculated by:
COUNT= DATA+1 ÷fCLK
(2)
After a reset, an additional 2 clock cycles is added for clock synchronization with an option to bypass. Note,
bypassing the clock synchronization can result in the counter resetting to an unknown value.
Note
Counters are initialized with DATA = 0 after POR.
Figure 7-15 and Figure 7-16 show examples of Counter output timing diagrams with respect to the Edge select
parameter with DATA = 1 and DATA = 3, respectively.
IN
CLK
OUT
(edge = rising)
OUT
(edge = falling)
OUT
(edge = both)
OUT
(edge = HLR)
Figure 7-15. Counter Output Timing Example (DATA = 1)
www.ti.com
TPLD1202
SCPS289B – SEPTEMBER 2024 – REVISED AUGUST 2026
Copyright © 2026 Texas Instruments Incorporated
Submit Document Feedback
49
Product Folder Links: TPLD1202



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com