DFR0972 Datasheet(HTML) 17 Page - DFROBOT

Back Button DFR0972 Datasheet HTML 11Page - DFROBOT DFR0972 Datasheet HTML 12Page - DFROBOT DFR0972 Datasheet HTML 13Page - DFROBOT DFR0972 Datasheet HTML 14Page - DFROBOT DFR0972 Datasheet HTML 15Page - DFROBOT DFR0972 Datasheet HTML 16Page - DFROBOT DFR0972 Datasheet HTML 17Page - DFROBOT DFR0972 Datasheet HTML 18Page - DFROBOT DFR0972 Datasheet HTML 19Page - DFROBOT  
Zoom Inzoom in Zoom Outzoom out
 17 / 19 page
background image
2023/10/12 15:11
I2C 4-20mA DAC Module Arduino Wiki - DFRobot
https://wiki.dfrobot.com/SKU_DFR0972_I2C_4_20mA_DAC_Module
17/19
void loop(){
}
Calibrate 4mA:
Set the parameter in the statement to 4 and output 4mA current: uint16_t dac = module.output(/*current_mA =**/4);
Download the code and check the actual output value of the ammeter.
If the actual output current is 4.05mA, then lower the DAC value 652 corresponding to 4mA in the code statement, for example, change
it to 645: module.calibration4_20mA(/*dac_4 =*/652, /*dac_20 =*/3265);
Redownload the code and check the actual current value. Repeatedly modify the DAC value until the measured current is exactly 4mA.
The calibration of 4mA is complete.
Calibrate 20mA:
Set the parameter in the statement to 20 and output 20mA current: uint16_t dac = module.output(/*current_mA =*/20);
Download the code and check the actual output value of the ammeter.
If the actual output current is 20.05mA, then lower the DAC value 3265 corresponding to 20mA in the statement, for example, change it
to 3260: module.calibration4_20mA(/*dac_4 =*/652, /*dac_20 =*/3265);
Redownload the code and check the actual current value. Repeatedly modify the DAC value until the measured current is exactly 20mA.
The calibration of 20mA is complete.
So the calibration of the current within 4-20mA is complete. The calibrated current value within 4-20mA can be output using this statement:
uint16_t dac = module.output(/*current_mA =*/10);



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com