| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ATC210 Datasheet(PDF) 14 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
ATC210 Datasheet(HTML) 14 Page - Emerson Network Power |
|
14 / 16 page ![]() Intermediate Bus Converters 14 File Name: atc210.pdf Rev: 16 Aug 2006 Pin Functionality Pin-Out Table Pin Number / Pin Name Function Note 1 -48V A Power input from ‘A’ bus Connects to ATCA Zone 1 connector pin 33 via external 10 A fuse 2 -48V B Power input from ‘B’ bus Connects to ATCA Zone 1 connector pin 34 via external 10 A fuse 3 Reserved For future use 4 Reserved For future use 5 RTN A Power return from ‘A’ bus Connects to ATCA Zone 1 connector pin 28 via external 12 A fuse 6 RTN B Power return from ‘B’ bus Connects to ATCA Zone 1 connector pin 29 via external 12 A fuse 7 ENA When connected to RTN A, turns ON Connects to ATCA Zone 1 connector pin 32 via external isolated open collector ‘A enabled’ device 1 A fuse. Used to signal to management system correct (See Note 3) board insertion and presence of ‘A’ bus 8 ENB When connected to RTN B, turns ON Connects to ATCA Zone 1 connector pin 27 via external isolated open collector ‘B enabled’ device 1 A fuse. Used to signal to management system correct (See Note 3) board insertion and presence of ‘B’ bus 9 C_CL- Connection to module of auxilliary Utilises greater capacitance in a given can size of lower capacitor hold up array -ve voltage capacitors. Clamped to –50 V wrt HU+OUT 10 HU- Connection to module of hold up capacitor array -ve 11 HU+OUT Connection from on board filter and May also connect to input of boost module to reduce management circuits to hold up hold up storage area capacitor array +ve 12 HU+IN Connection to main power converter from May also connect to output of boost module to reduce hold hold up capacitor array +ve up storage area 13 ON/OFF- Current from pin to turn main output ON Fully floating remote ON/OFF signal, may be used with management system or ATCA ENABLE_A/B via R-D network 14 ON/OFF+ Current into pin to turn main output ON Fully floating remote ON/OFF signal, may be used with management system or ATCA ENABLE_A/B via R-D network 15 B_OK# Open collector signal, monitors status of Low when “OK” “B” feed 16 A_OK# Open collector signal, monitors status of Low when “OK” “B” feed 17 A2 I2C lines, address strapping 18 INTRPT Interrupt Alarm I2C Register out of limits, LM80 pin ‘INT#’ direct connection 19 A1 I2C lines, address strapping 20 SCL Clock I2C lines, clock line input 21 A0 I2C lines, address strapping 22 SDA Data I2C lines, serial data 23, 24 3V3 RTN Management power return and I2C Also return for ‘A _OK#’ and ’B_OK#’ signals. Externally connected to ATCA Zone 1 connector pin 26 25, 26 3V3 OUT 3V3, 6 W management power 27, 28 3V3 TRIM Trim pin for management power 29 12V RTN 12 V return Externally connected to ATCA Zone 1 connector pin 26 30 12V OUT 12 V power ATC210 Dual Series | 210 W DC-DC |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |