| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
33902 Datasheet(PDF) 15 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
33902 Datasheet(HTML) 15 Page - Freescale Semiconductor, Inc |
|
15 / 31 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 15 33902 FUNCTIONAL DEVICE OPERATION OPERATIONAL MODES DEVICE STATE DESCRIPTION STANDBY MODE Standby mode is a reduced current consumption mode. CANH and CANL lines are terminated to GND, the SPLIT pin is high-impedance. In order to monitor bus activities, the CAN wake-up receiver is ON, INH output remains ON. The voltage on VIO should be maintained. The VDD regulator is ON with limited current capability, in order to maintain the capacitor at VDD charged and allow a fast transition to Normal mode and fast CAN communication. Wake-up events occurring on the CAN bus or on the WAKE pin are reported by a low level of the ERR and RXD pins. The Standby mode is also the first mode entered after a device power up. In this case, the VDD regulator is activated to charge the VDD capacitor, and then the regulator enters the reduced current capability mode, in order to optimize and reduce system current consumption. Depending upon the VDD capacitor ‘s Equivalent Series Resistance (ESR), a voltage drop can be observed. See Figure 10. Figure 10. VDD Regulator Start-up NORMAL MODE In Normal mode, both the CAN driver and receiver are ON. In this mode, the CAN bus is controlled by the TXD pin level, and the CAN bus state is reported on the RXD pin. The VDD regulator is ON. It supplies the CAN driver and receiver.The SPLIT pin is active and a 2.5 V biasing is provided on the SPLIT output pin. In Normal mode, the ERR pin reports the wake-up source and the bus failure, after 4 TXD pulses. Normal mode is entered by setting the EN and STBY pins high. Entering Normal mode will clear the BATFAIL flag. LISTEN ONLY MODE This mode is used to disable the CAN driver, but leave the CAN receiver active. In this mode, the device is only able to report the CAN state on the RXD pin. The TXD pin has no effect on CAN bus lines. This mode is entered by setting the EN and STBY pins to [0, 1]. In this mode, coming from Normal mode, the ERR pin reports local failures occurring on the TXD and RXD pins, and VDD low. When this mode is entered from the Standby mode, the ERR pin reports the BATFAIL flag. The VDD regulator is ON. The SPLIT pin is active and a 2.5 V biasing is provided on the SPLIT output pin. GO TO SLEEP MODE Go to sleep is an intermediate mode to ultimately set the device in Sleep mode. The go to sleep is entered by setting the EN and STBY pins to [1, 0]. If the EN and STBY pins are maintained to [1,0] for a time longer than tH, the Sleep mode is automatically entered. In go to Sleep mode, the VDD regulator remains in its previous state and the SPLIT pin is deactivated. INH is active. SLEEP MODE The Sleep mode is a low power mode. It is entered from the Go To Sleep mode by setting the EN and STBY pins to [1 0], and automatically from Go To Sleep mode after tH. In Sleep mode, the VDD regulator is turned off and the SPLIT pin is deactivated, INH is high-impedance. In Sleep mode and Go To Sleep mode, the device is able to wake-up on CAN bus activity or transitions on the WAKE pin. A wake-up from Sleep mode will set the device in Standby mode. Sleep mode is also automatically reached if the voltage at VIO is below the VIOTH for more time than TVIO-SLP. DEVICE MAIN FLAGS DESCRIPTION: This section describes the flags available when the device is controlled via the EN and STBY pins in a static manner (no P_SPI control). Additional information and control are possible using the Pseudo SPI (refer to Extended device operation). BATFAIL This flag is set to signal that the voltage on the VSUP pin has dropped below VBFTHS, particularly after the device was disconnected from the battery. In Listen Only mode, the BATFAIL flag will be available on the ERR pin, coming from standby, Go To Sleep and Sleep modes. When VSUP is below VBF threshold, all internal flags and registers are reset to their initial condition. CAN Bus Wake-up (WU) From Standby or Sleep mode, this flag is set if a correct pattern has been received on the CAN bus. This wake-up is reported on ERR and RXD pins by a low level in Standby mode, as well as in Sleep mode if VIO is present. VDD low (4.25 V) 5V EN, STBY VE = esr x VDD current limitation VE VE VE wake-up event detected device start-up 0V Standby Normal Sleep Main VDD Weak regulator ON ON Main VDD ON Main regulator OFF |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |