| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
AD9550 Datasheet(PDF) 17 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9550 Datasheet(HTML) 17 Page - Analog Devices |
|
17 / 20 page ![]() AD9550 Rev. 0 | Page 17 of 20 APPLICATIONS INFORMATION THERMAL PERFORMANCE The AD9550 is specified for case temperature (TCASE). To ensure that TCASE is not exceeded, use an airflow source. The following equation determines the junction temperature on the application printed circuit board (PCB): TJ = TCASE + (ΨJT × PD) where: TJ is the junction temperature (°C). TCASE is the case temperature (°C) measured by the customer at the top center of the package. ΨJT is the value indicated in Table 11. PD is the power dissipation (see Table 1 for the power consumption parameters). Values of θJA are provided for package comparison and PCB design considerations. θJA can be used for a first-order approximation of TJ using the following equation: TJ = TA + (θJA × PD) where TA is the ambient temperature (°C). Values of θJC are provided for package comparison and PCB design considerations when an external heat sink is required. Values of θJB are provided for package comparison and PCB design considerations. Table 11. Thermal Parameters for the 32-Lead LFCSP Symbol Description Value1 Unit θ JA Junction-to-ambient thermal resistance, 0 m/sec airflow per JEDEC JESD51-2 (still air) 41.6 °C/W θ JMA Junction-to-ambient thermal resistance, 1.0 m/sec airflow per JEDEC JESD51-6 (moving air) 36.4 °C/W θ JMA Junction-to-ambient thermal resistance, 2.5 m/sec airflow per JEDEC JESD51-6 (moving air) 32.6 °C/W θ JB Junction-to-board thermal resistance, 0 m/sec airflow per JEDEC JESD51-8 (still air) 24.2 °C/W Ψ JB Junction-to-board characterization parameter, 0 m/sec airflow per JEDEC JESD51-6 (still air) 22.9 °C/W θ JC Junction-to-case thermal resistance 4.8 °C/W Ψ JT Junction-to-top-of-package characterization parameter, 0 m/sec airflow per JEDEC JESD51-2 (still air) 0.5 °C/W 1 Results are from simulations. The PCB is a JEDEC multilayer type. Thermal performance for actual applications requires careful inspection of the conditions in the application to determine whether they are similar to those assumed in these calculations. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |