39 / 46 page ![]() CS5464 DS682F3 39 9. SYSTEM CALIBRATION 9.1 Calibration The CS5464 provides DC offset and gain calibration that can be applied to the voltage and current measure- ments, and AC offset calibration which can be applied to the voltage and current RMS calculations. Since the voltage and current channels have indepen- dent offset and gain registers, offset and gain calibra- tion can be performed on any channel independently. The data flow of the calibration is shown in Figure 10. The CS5464 must be operating in its active state and ready to accept valid commands. Refer to 7.6 Com- mands on page 24. The value in the Cycle Count register (N) determines the number of output word rate (OWR) samples that are averaged during a calibration. DC offset and gain cali- brations take at least N + TSETTLE samples. AC offset calibrations take at least 6(N)+ TSETTLE samples. As N is increased, the accuracy of calibration results tends to also increase. The DRDY bit in the Status register will be set at the completion of Calibration commands. If an overflow oc- curs during calibration, other Status register bits may be set as well. 9.1.1 Offset Calibration During offset calibrations, no line voltage or current should be applied to the meter. A zero-volt differential signal can also be applied to the voltage inputs VIN or current inputs IIN1 (IINof the CS5464. (see Figure 11.) 9.1.1.1 DC Offset Calibration The DC Offset Calibration command measures and av- erages DC values read on specified voltage or current channels at zero input and stores the inverse result in the associated offset registers. This will be added to in- stantaneous measurements in subsequent conver- sions, removing the offset. Gain registers for channels being calibrated should be set to 1.0 prior to performing DC offset calibration. 9.1.1.2 AC Offset Calibration The AC Offset Calibration command measures the re- sidual RMS values read on specified voltage or current channels at zero input and stores the inverse result in the associated AC offset registers. This will be added to RMS measurements in subsequent conversions, re- moving the offset. AC offset registers for channels being calibrated should first be cleared prior to performing the calibration. In Modulator + X V1, I1, V2, I2 Filter N I1RMS, V1RMS, I2RMS, V2RMS I1DCOFF, V1DCOFF, I2DCOFF, V2DCOFF I1GAIN, V1GAIN, I2GAIN, V2GAIN 0.6 + = READABLE/WRITABLE REGISTERS. N + X N 1 DCAVG RMS I1ACOFF, V1ACOFF, I2ACOFF, V2ACOFF N + DC Gain DC Offset AC Offset RMS AC Gain Negate DC AVG Negate Figure 10. Calibration Data Flow + - XGAIN + - External Connections 0V + - AIN+ AIN- CM + - Figure 11. System Calibration of Offset |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |