| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ADM1032ARM Datasheet(PDF) 2 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1032ARM Datasheet(HTML) 2 Page - Analog Devices |
|
2 / 12 page ![]() REV. 0 –2– ADM1032–SPECIFICATIONS (T A = TMIN to TMAX, VDD = VMIN to VMAX, unless otherwise noted.) Parameter Min Typ Max Unit Test Conditions/Comments POWER SUPPLY Supply Voltage, VDD 3.0 3.30 5.5 V Average Operating Supply Current, ICC 170 215 µA 0.0625 Conversions/Sec Rate 1 5.5 10 µA Standby Mode Undervoltage Lockout Threshold 2.35 2.55 2.8 V VDD Input, Disables ADC, Rising Edge Power-On Reset Threshold 1 2.4 V TEMPERATURE-TO-DIGITAL CONVERTER Local Sensor Accuracy ±1 ±3 °C0 ≤ T A ≤ 100°C, V CC = 3 V to 3.6 V Resolution 1 °C Remote Diode Sensor Accuracy ±1 °C60°C ≤ TD ≤ 100°C, VCC = 3 V to 3.6 V ±3 °C0°C ≤ T D ≤ 120°C Resolution 0.125 °C Remote Sensor Source Current 230 µA High Level, Note 2 13 µA Low Level, Note 2 Conversion Time 35.7 142.8 ms From Stop Bit to Conversion Complete (Both Channels) One-Shot Mode with Averaging Switched On 5.7 22.8 ms One-Shot Mode with Averaging Off (i.e., Conversion Rate = 32 or 64 Conversions per Second) OPEN-DRAIN DIGITAL OUTPUTS ( THERM, ALERT) Output Low Voltage, VOL 0.4 V IOUT = –6.0 mA 2 High Level Output Leakage Current, IOH 0.1 1 µAV OUT = VDD 2 SMBus INTERFACE 2 Logic Input High Voltage, VIH 2.1 V VDD = 3 V to 5.5 V SCLK, SDATA Logic Input Low Voltage, VIL 0.8 V VDD = 3 V to 5.5 V Hysteresis 500 mV SCLK, SDATA SMBus Output Low Sink Current 6 mA SDATA Forced to 0.6 V ALERT Output Low Sink Current 1 mA ALERT Forced to 0.4 V Logic Input Current, IIH, IIL –1 +1 µA SMBus Input Capacitance, SCLK, SDATA 5 pF SMBus Clock Frequency 100 kHz SMBus Timeout 25 64 ms Note 3 SMBus Clock Low Time, tLOW 4.7 µstLOW between 10% Points SMBus Clock High Time, tHIGH 4 µst HIGH between 90% Points SMBus Start Condition Setup Time, tSU:STA 4.7 µs SMBus Start Condition Hold Time, tHD:STA 4 µs Time from 10% of SDATA to 90% of SCLK SMBus Stop Condition Setup Time, tSU:STO 4 µs Time from 90% of SCLK to 10% of SDATA SMBus Data Valid to SCLK Rising Edge 250 ns Time for 10% or 90% of SDATA to Time, tSU:DAT 10% of SCLK SMBus Data Hold Time, tHD:DAT 300 µs SMBus Bus Free Time, tBUF 4.7 µs Between Start/Stop Condition SCLK Falling Edge to SDATA 1 µs Master Clocking in Data Valid Time, tVD,DAT SCLK, SDATA Rise Time, tR 1 µs SCLK, SDATA Fall Time, tF 300 ns NOTES 1See Table VI for information on other conversion rates. 2Guaranteed by Design, not production tested. 3The SMBus timeout is a programmable feature. By default it is not enabled. Details on how to enable it are available in the SMBus section of this data sheet. Specifications subject to change without notice. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |