20 / 37 page ![]() ADIS16000/ADIS16229 Preliminary Technical Data Rev. PrA | Page 20 of 37 Scale Adjustment The x_SENS registers (see Table 32 and Table 33) provide a fine-scale adjustment function for each axis. The following equation describes how to use measured and ideal values to calculate the scale factor for each register in LSBs: SCFx = 1 XM XI a a × 218 where: XI a is the ideal x-axis value. XM a is the actual x-axis measurement. These registers contain correction factors, which come from the factory calibration process. The calibration process records accelerometer output in four different orientations and computes the correction factors for each register. These registers also provide write access for in-system adjust- ment. Gravity provides a common stimulus for this type of correction process. Use both +1 g and −1 g orientations to reduce the effect of offset on this measurement. In this case, the ideal measurement is 2 g, and the measured value is the difference of the accelerometer measurements at +1 g and −1 g orientations. The factory-programmed values are stored in flash memory and are restored by setting GLOB_CMD[3] = 1 (DIN = 0xB604) (see Table 74). Table 32. X_SENS Pages 1-6, Low Byte Address = 0x16, Read/Write Bits Description (Default = N/A) [15:0] X-axis scale correction factor (SCFx), twos complement Table 33. Y_SENS Pages 1-6, Low Byte Address = 0x18, Read/Write Bits Description (Default = N/A) [15:0] Y-axis scale correction factor (SCFy), twos complement PRE-FFT WINDOWING REC_CTRL1[13:12] provide three options for pre-FFT windowing of time data. For example, set REC_CTRL1[13:12] = 01 to use the Hanning window, which offers the best amplitude resolution of the peaks between frequency bins and minimal broadening of peak amplitudes. The rectangular and flat top windows are also available because they are common windowing options for vibration monitoring. The flat top window provides accurate amplitude resolution with a trade-off of broadening the peak amplitudes. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |