| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
AM79C985JC Datasheet(PDF) 27 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C985JC Datasheet(HTML) 27 Page - Advanced Micro Devices |
|
27 / 48 page ![]() Am79C985 27 PRELIMINARY TP Port Disable SI Data 0010 0### SO Data (Pri) None SO Data (Sec) None This command disables the TP port designated by the three least-significant bits of the command byte. Sub- sequently the eIMR+ chip will ignore all inputs to the designated port and will not transmit a DAT or JAM pat- tern on that port. Disabling the TP port also sets the partitioning state machine of that port to the idle state. Therefore, a partitioned port can be reconnected by first disabling the port and then enabling it. Designated port values of b111 through b100 in the command byte cor- respond to TP7 through TP4 in the primary eIMR+ de- vice. Designated port values of b011 through b000 in the command byte correspond to TP3 through TP0 in the secondary eIMR+ device. TP Port Enable SI Data 0011 0### SO Data (Pri) None SO Data (Sec) None This command enables the TP port designated by the three least-significant bits of the command byte. Desig- nated port values of b111 through b100 in the command byte correspond to TP7 through TP4 in the primary eIMR+ device. Designated port values of b011 through b000 in the command byte correspond to TP3 through TP0 in the secondary eIMR+ device. Disable Link Test Function (per TP port) SI Data 0100 0### SO Data (Pri) None SO Data (Sec) None This command disables the Link test function of the TP port designated by the three least-significant bits of the command data. As a consequence of this, the port will no longer be disconnected if it fails the Link Test. If a port has the Link Test disabled, reading the Link Test Status indicates a ‘Link Pass’. Designated port values of b111 through b100 in the command byte correspond to TP7 through TP4 in the primary eIMR+ device. Des- ignated port values of b011 through b000 in the com- mand data correspond to TP3 through TP0 in the secondary eIMR+ device. Enable Link Test Function (per TP port) SI Data 0101 0### SO Data (Pri) None SO Data (Sec) None This command enables the Link test function of the TP port designated by the three least-significant bits of the command data. As a consequence of this, the port is disconnected if it fails the Link Test. Designated port values of b111 through b100 in the command byte cor- respond to TP7 through TP4 in the primary eIMR+ device. Designated port values of b011 through b000 in the command data correspond to TP3 through TP0 in the secondary eIMR+ device. Disable Link Pulse (Per TP Port) SI Data 0100 1### SO Data (Pri) None SO Data (Sec) None This command disables the transmission of the Link pulse on the TP port designated by the three least-sig- nificant bits of the command byte. Designated port val- ues of b111 through b100 in the command byte correspond to TP7 through TP4 in the primary eIMR+ device. Designated port values of b011 through b000 in the command data correspond to TP3 through TP0 in the secondary eIMR+ device. Enable Link Pulse (Per TP Port) SI Data 0101 1### SO Data (Pri) None SO Data (Sec) None This command enables the transmission of the Link pulse on the TP port designated by the three least-sig- nificant bits of the command byte. Designated port val- ues of b111 through b100 in the command byte correspond to TP7 through TP4 in the primary eIMR+ device. Designated port values of b011 through b000 in the command byte correspond to TP3 through TP0 in the secondary eIMR+ device. Disable Automatic Receiver Polarity Reversal (Per TP Port) SI Data 0110 0### SO Data (Pri) None SO Data (Sec) None This command disables the Automatic Receiver Polar- ity Reversal function for the TP port designated by the three least-significant bits in the command byte. If this function is disabled on a TP port receiving with reversed polarity (due to a wiring error), the TP port will fail the Link Test due to the incorrect polarity of the received Link pulses. Designated port values of b111 through b100 in the command byte correspond to TP7 through TP4 in the primary eIMR+ device. Designated port val- ues of b011 through b000 in the command byte corre- spond to TP3 through TP0 in the secondary eIMR+ device. The state of Automatic Polarity Reversal function is set by SI on reset. If SI is HIGH at the rising edge of RST, the eIMR+ device disables Automatic Polarity Reversal. If SI is LOW at the rising edge of RST, the eIMR+ device enables Automatic Polarity Reversal. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |