13 / 42 page ![]() 5/4/98 AmC0XXCFLKA 13 or sectors the remaining unselected sectors are not af- fected. The system is not required to provide any con- trols or timings during these operations. A Reset command after the device has begun execution will stop the device but the data in the operated segment will be undefined. In that case, restart the erase on that sector and allow it to complete. The automatic sector erase begins after the 100 µs time out from the rising edge of the WE pulse for the last sector erase command pulse and terminates when the data on D7 is “1” (see “Write Operation Status” sec- tion) at which time the device returns to read mode. Data Polling must be performed at an address within any of the sectors being erased. Figure 1 illustrates the Embedded Erase Algorithm using typical command strings and bus operations. Embedded Program™ Algorithm The Embedded Program Setup is a four bus cycle op- eration that stages the addressed memory sector or memory segment for automatic programming. Once the Embedded Program Setup operation is per- formed, the next WE pulse causes a transition to an ac- tive programming operation. Addresses are internally latched on the falling edge of the WE pulse. Data is in- ternally latched on the rising edge of the WE pulse. The rising edge of WE also begins the programming opera- tion. The system is not required to provide further con- trol or timing. The device will automatically provide an adequate internally generated write pulse and verify margin. The automatic programming operation is com- pleted when the data on D7 of the addressed memory sector or memory segment is equivalent to data written to this bit (see Write Operation Status section) at which time the device returns to the Read mode (no write ver- ify command is required). Addresses are latched on the falling edge of WE during the Embedded Program command execution and hence the system is not required to keep the addresses stable during the entire Programming operation. How- ever, once the device completes the Embedded Pro- gram operation, it returns to the Read mode and addresses are no longer latched. Therefore, the device requires that a valid address input to the device is sup- plied by the system at this particular instant of time. Otherwise, the system will never read a valid data on D7. A system designer has two choices to implement the Embedded Programming algorithm: 1. The system (CPU) keeps the address valid during the entire Embedded Programming operation, or 2. Once the system executes the Embedded Program- ming command sequence, the CPU takes away the address from the device and becomes free to do other tasks. In this case, the CPU is required to keep track of the valid address by loading it into a temporary register. When the CPU comes back for performing Data Polling, it should reassert the same address. However, since the Embedded Programming operation takes only 16 µs typically, it may be easier for the CPU to keep the address stable during the entire Embedded Programming operation instead of reasserting the valid address during Data Polling. Anyway, this has been left to the system designer’s choice to go for either opera- tion. Any commands written to the segment during this period will be ignored. Figure 2 and Table 8 illustrate the Embedded Program Algorithm, a typical command string, and bus operation. Reset Command The Reset command initializes the sector or segment to the read mode. Please refer to Tables 3 and 4, “Byte Command Definitions,” and Table 5, “Word Command Definitions” for the Reset command operation. The sector or segment remains enabled for reads until the command register contents are altered. There is a 6 µs Write Recovery Time before Read for the first read after a write. The Reset command will safely reset the segment memory to the Read mode. Memory contents are not altered. Following any other command, write the Reset command once to the segment. This will safely abort any operation and reset the device to the Read mode. The Reset is needed to terminate the auto select oper- ation. It can be used to terminate an Erase or Sector Erase operation, but the data in the sector or segment being erased would then be undefined. Write Operation Status Data Polling—D7 (D15 on Odd Byte) The Flash Memory PC Card features Data Polling as a method to indicate to the host system that the Embed- ded algorithms are either in progress or completed. While the Embedded Programming algorithm is in op- eration, an attempt to read the device will produce the complement of expected valid data on D7 of the ad- dressed memory sector or memory segment. Upon Table 8. Embedded Program Algorithm Bus Operation Command Comments Standby Wait for VCC ramp Write Embedded Program command sequence 3 bus cycle operation Write Program Address/Data 1 bus cycle operation Read Data Polling to verify program |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |