| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
NIPXIE4331 Datasheet(PDF) 7 Page - National Instruments Corporation |
|
|
|||||||||||||||||||||||||||||
NIPXIE4331 Datasheet(HTML) 7 Page - National Instruments Corporation |
|
7 / 9 page ![]() 7/9 www.ni.com Digital trigger Source PXI_TRIG<0..7>, PXI_STAR, PXIe_DSTAR<A..B> Purpose Start or reference trigger Polarity Software-selectable Debounce filter settings Disable, 90 ns, 5.12 μs, 2.56 ms, custom interval Output timing signals Sources Sample Clock, Start Trigger Out, Reference Trigger Out Destinations PXI_TRIG<0..7>, PXIe_DSTAR C Polarity Software-selectable Output Timing Signals Sources Sample Clock, Start Trigger Out, Reference Trigger Out Destinations PXI_TRIG<0..7>, PXIe_DSTAR C Polarity Software-selectable Bus Interface Form factor x1 PXI Express peripheral module, Specification rev 1.0 compliant Slot compatibility x1 and x4 PXI Express or PXI Express hybrid slots DMA channels 1, analog input Calibration You can obtain the calibration certificate and information about calibration services for the NI PXIe-4330 at . ni.com/calibration Recommended warm-up time 15 minutes Calibration interval 1 year Power Requirements +12 V 1.3 A +3.3 V 1.1 A Physical Requirements Dimensions Standard 3U PXIe, 16 × 10 cm (6.3 × 3.9 in.) Weight 152 g (5.3 oz) I/O connector 96-pin male DIN 41612/IEC 60603-2 connector. Environmental Specifications Maximum altitude 2,000 m (800 mbar), (at 25 °C ambient temperature) Pollution Degree 2 Indoor use only Operating Environment Ambient temperature range 0 to 55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) Relative humidity range 10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) Storage Environment Ambient temperature range –40 to 71°C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 limits.) Relative humidity range 5% to 95%, noncondensing (Tested in accordance with IEC-60068-2-56.) |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |