| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
STC3105 Datasheet(PDF) 16 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STC3105 Datasheet(HTML) 16 Page - STMicroelectronics |
|
16 / 23 page ![]() I2C interface STC3105 16/23 Doc ID 022198 Rev 1 7.2 Register map The register space provides 17 control registers, 1 read-only register for device ID and 16 read/write RAM working registers reserved for the gas gauge algorithm. Mapping of all registers is shown in Table 10. Detailed descriptions of registers 0 (REG_MODE) and 1 (REG_CTRL) are shown in Table 11 and Table 12. All registers are reset to default values at power-on or reset, and the PORDET bit in register REG_CTRL is used to indicate the occurrence of a power-on reset. Values held in consecutive registers (such as the charge value in the REG_CHARGE_LOW and REG_CHARGE_HIGH registers) must be read with a single I2C access to ensure data integrity. It is possible to read multiple values in one I2C access; all values will be consistent. Table 10. Register map Name Address (decimal) Type Description Control registers 0 to 23 REG_MODE 0 R/W Mode register REG_CTRL 1 R/W Control and status register REG_CHARGE_LOW 2 R State-of-charge data, bits 0-7 REG_CHARGE_HIGH 3 R State-of-charge data, bits 8-15 REG_COUNTER_LOW 4 R Number of conversions, bits 0-7 REG_COUNTER_HIGH 5 R Number of conversions, bits 8-15 REG_CURRENT_LOW 6 R Battery current value, bits 0-7 REG_CURRENT_HIGH 7 R Battery current value, bits 8-15 REG_VOLTAGE_LOW 8 R Battery voltage value, bits 0-7 REG_VOLTAGE_HIGH 9 R Battery voltage value, bits 8-15 REG_SOC_BASE_LOW 10 R/W SOC base value, bits 0-7 REG_SOC_BASE_HIGH 11 R/W SOC base value, bits 8-15 REG_ALARM_SOC_LOW 12 R/W SOC alarm level, bits 0-7 REG_ALARM_SOC_HIGH 13 R/W SOC alarm level, bits 8-15 REG_ALARM_VOLTAGE 14 R/W Battery low voltage alarm level REG_CURRENT_THRES 15 R/W Current threshold for the voltage relaxation counter REG_RELAX_COUNT 16 R Voltage relaxation counter Device ID register REG_ID 24 R Part type ID = 12h RAM registers 32 to 47 REG_RAM0 32 R/W Working register 0 for gas gauge ... ... ... REG_RAM15 47 R/W Working register 15 for gas gauge |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |