21 / 26 page ![]() AN3157 3-phase systems Doc ID 17105 Rev 1 21/26 A.2.2 Three-wattmeter method This method is used in a 3-phase four-wire balanced or unbalanced load. The connections are made with one meter in each line as shown in Figure 15. In this configuration, the total active power supplied to the load is equal to the sum of the three wattmeter readings. A.2.3 One wattmeter method This method is suitable only in 3-phase four-wire balanced loads. The connection of the wattmeter is similar to the drawing in Figure 15. The total power is equal to three times the reading of only one wattmeter which is connected between one phase and neutral. 3 2 1 Total P P P P + + = Figure 15. The wattmeter connections in 3-phase four-wire loads |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|