6 / 8 page ![]() Switched-Capacitor Voltage Inverters 6 _______________________________________________________________________________________ Conversion losses occur during the charge transfer between C1 and C2 when there is a voltage difference between them. The power loss is: __________Applications Information Capacitor Selection To maintain the lowest output resistance, use capaci- tors with low ESR (Table 1). The charge-pump output resistance is a function of C1’s and C2’s ESR. Therefore, minimizing the charge-pump capacitor’s ESR minimizes the total output resistance. Flying Capacitor (C1) Increasing the flying capacitor’s size reduces the out- put resistance. Small C1 values increase the output resistance. Above a certain point, increasing C1’s capacitance has a negligible effect, because the out- put resistance becomes dominated by the internal switch resistance and capacitor ESR. Output Capacitor (C2) Increasing the output capacitor’s size reduces the out- put ripple voltage. Decreasing its ESR reduces both output resistance and ripple. Smaller capacitance val- ues can be used with light loads if higher output ripple can be tolerated. Use the following equation to calcu- late the peak-to-peak ripple: Input Bypass Capacitor Bypass the incoming supply to reduce its AC impedance and the impact of the MAX828/MAX829’s switching noise. The recommended bypassing depends on the cir- cuit configuration and on where the load is connected. When the inverter is loaded from OUT to GND, current from the supply switches between 2 x IOUT and zero. Therefore, use a large bypass capacitor (e.g., equal to the value of C1) if the supply has a high AC impedance. When the inverter is loaded from IN to OUT, the circuit draws 2 x IOUT constantly, except for short switching spikes. A 0.1µF bypass capacitor is sufficient. Voltage Inverter The most common application for these devices is a charge-pump voltage inverter (Figure 1). This applica- tion requires only two external components—capacitors C1 and C2—plus a bypass capacitor, if necessary. Refer to the Capacitor Selection section for suggested capacitor types and values. Cascading Devices Two devices can be cascaded to produce an even larger negative voltage (Figure 4). The unloaded output voltage is normally -2 x VIN, but this is reduced slightly by the output resistance of the first device multiplied by the quiescent current of the second. When cascading more than two devices, the output resistance rises dra- matically. For applications requiring larger negative voltages, see the MAX864 and MAX865 data sheets. Paralleling Devices Paralleling multiple MAX828s or MAX829s reduces the output resistance. Each device requires its own pump capacitor (C1), but the reservoir capacitor (C2) serves all devices (Figure 5). Increase C2’s value by a factor of n, where n is the number of parallel devices. The equation for calculating output resistance is also shown in Figure 5. V = I f x C2 RIPPLE OUT OSC + 2 2 x I x ESR OUT C P C1 V V C2 V 2V V x f CONV.LOSS IN 2 OUT 2 RIPPLE 2 OUT RIPPLE OSC [ ] = − + − 1 2 1 2 / / Table 1. Low-ESR Capacitor Manufacturers Matsuo AVX MANUFACTURER (714) 969-2491 (803) 946-0690 (800) 282-4975 PHONE (603) 224-1961 (619) 661-6835 Sprague Sanyo (603) 224-1430 (619) 661-1055 (714) 960-6492 (803) 626-3123 FAX Surface-mount, 595D series Through-hole, OS-CON series Surface-mount, 267 series Surface-mount, TPS series DEVICE TYPE USA Japan 81-7-2070-6306 81-7-2070-1174 |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |