| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
TMC150 Datasheet(PDF) 1 Page - Tumbler Technologies + TRUMPower |
|
|
|||||||||||||||||||||||||||||
TMC150 Datasheet(HTML) 1 Page - Tumbler Technologies + TRUMPower |
|
1 / 2 page ![]() TMC150 Series 150 Watts AC/DC Medical & ITE Grade Power Supplies TRUMPower Tumbler Technologies + TRUMPower 3350 Scott Blvd., Building 13 • Santa Clara, California 95054, USA • 408-988-6616 • sales@trumpower.com • www.TRUMPower.com INPUT SPECIFICATIONS Input Voltage Range .............. 90-264 VAC Input Frequency ..................... 47-63 Hz Input Current .......................... 1.7A rms @ 115 VAC, 0.85A rms @ 230 VAC Inrush Current ....................... 80A @ 115 VAC or 160A @ 230 VAC, at 25°C cold start Earth Leakage Current .......... 105 µA max. @ 264 VAC, 63 Hz OUTPUT SPECIFICATIONS Output Power Ratings ........... See table Minimum Load ...................... Not required Tolerance ............................... ±2% Ripple and Noise* ................. 1% Vp-p, 20 MHz bandwidth Remote Sense ...................... Compensates cable losses up to 0.5V Overvoltage Protection .......... Set at 112-140% of its nominal output voltage Overcurrent Protection .......... Protected to short-circuit conditions Temperature Coefficient ....... ±0.04%/°C max. Transient Response ............. Max. excursion of 4% or better on all models, recovering to 1% of final value within 500 µs after a 25% step load change No Load Power Cons. .......... <0.5W w/o PFD, <1W with PFD * Measured with a 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor at rated line voltage and load ranges. FEATURES • 2" x 4" x 1.2" Open Frame • Low Leakage Current • BF Rated Outputs • Remote Sense & Optional PFD • 0.5W No Load Power Consumption GENERAL SPECIFICATIONS Switching Frequency ............. 133 kHz typical Power Factor ......................... 0.98 typical, with active PFC Efficiency ............................... 87% typical @ 115 VAC, 89% typical @ 230 VAC Hold-up Time ......................... 10 ms min. @ 120 VAC Operating Altitude .................. 5,000 meters max. Line Regulation ..................... ±0.5% max. @ full load Operating Temperature ........ 0°C to +70°C Derating ................................. Derate from 100% @ +50°C linearly to 50% @ +70°C, applicable to convection and forced-air cooling conditions Storage Temperature ............ -40°C to +85°C Relative Humidity .................. 5% to 95% non-condensing Withstand Voltage ................. 4,000 VAC, input-output (2 MOPP) 1,500 VAC, input-ground (1 MOPP) 1,500 VAC, output-ground MTBF ...................................... 250 kHrs minimum at full load, 25°C ambient, calculated per MIL-HDBK-217F STANDARDS & COMPLIANCES EN55011, EN55022 .......... Class B conducted, Class A radiated FCC .................................... Class B conducted, Class A radiated VCCI ................................... Class B conducted, Class A radiated EN61000-3-2 ..................... Harmonic distortion, Class A & D EN61000-3-3 ..................... Line flicker EN61000-4-2 ..................... ESD, ±8 KV air and ±6 KV contact EN61000-4-3 ..................... Radiated immunity, 3V/m EN61000-4-4 ..................... Fast transient/burst, ±2 KV EN61000-4-5 ..................... Surge, ±1 KV diff., ±2 KV com. EN61000-4-6 ..................... Conducted immunity, 3 Vrms EN61000-4-8 ..................... Magnetic field immunity, 3A/m EN61000-4-11 ................... Voltage dips immunity, 30% reduction for 500ms, 60% reduction for 100ms, >95% reduction for 10ms Safety Standards ............... IEC/EN 60601-1 (3rd Edition), ANSI/AAMI ES 60601-1:2005, CSA C22.2 No. 60601-1:08; UL/IEC/EN 60950-1 (2nd Edition), CSA C22.2 No. 60950-1 (2nd Edition) Agency Approvals .............. UL, cUL, TUV, CB, CE Other Compliance ............. RoHS MODELS LIST . o N t c u d o r P ) 1 ( t u p t u O e g a t l o V r e w o P t u p t u O m u m i x a M ) 2 ( n o i t c e v n o C @ M F C 5 . 7 @ t n e r r u C e g a t t a W t n e r r u C e g a t t a W 2 1 S - 0 5 1 C M T V 2 1A 5 3 . 8W 0 0 1A 5 . 2 1W 0 5 1 5 1 S - 0 5 1 C M T V 5 1A 7 . 6W 0 0 1A 0 1W 0 5 1 8 1 S - 0 5 1 C M T V 8 1A 6 5 . 5W 0 0 1A 4 3 . 8W 0 5 1 4 2 S - 0 5 1 C M T V 4 2A 2 . 4W 0 0 1A 5 2 . 6W 0 5 1 0 3 S - 0 5 1 C M T V 0 3A 4 3 . 3W 0 0 1A 5W 0 5 1 6 3 S - 0 5 1 C M T V 6 3A 8 7 . 2W 0 0 1A 7 1 . 4W 0 5 1 8 4 S - 0 5 1 C M T V 8 4A 1 . 2W 0 0 1A 3 1 . 3W 0 5 1 Notes: 1. Add suffix F to the P/N to order units with PFD, e.g. TMC150-S24F. 2. 168W peak power with 10% duty cycle maximum for less than 15 seconds with the average output not to exceed the maximum power rating. |
Número de pieza similar - TMC150 |
|
Descripción similar - TMC150 |
|
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |