6 / 16 page ![]() 2010-04-13 6 SCDQ5541P/Q/R, SCDQ5542P/Q/R, SCDQ5543P/Q/R, SCDQ5544P/Q/R Close Up of Data “Write” Cycle Device Timing Write Cycle Timing (over operating temperature range, V CC=VLL=4.5 V to 5.5 V) Symbol Description Min. Max. Units T LDS Load Setup Time 50 — ns T DS Data Setup Time 50 — ns T SDCLK Clock Period 200 — ns T SDCW (HI or LOW) Clock Width 70 — ns T LDH Load Hold Time 0 — ns T DH Data Hold Time 25 — ns T WR Total Write Time 2.25 — µs T BL Time Between Writes 600 — ns T RST Reset Active Time 600 — ns Notes: 1. T WR=Setup Time + 8 Clock Times + Hold Times + Time Between Writes. 2. Data is shifted into the display’s 8 bit shift register on the positive going edge of the SDCLK. 3. Shift register data is evaluated when Load goes high. LOAD LOAD DATA DATA SDCLK SDCLK D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7 D0 D0 BL T WR T OR |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|