| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
PA89 Datasheet(PDF) 4 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
PA89 Datasheet(HTML) 4 Page - Cirrus Logic |
|
4 / 4 page ![]() APEX MICROTECHNOLOGY CORPORATION • 5980 NORTH SHANNON ROAD • TUCSON, ARIZONA 85741 • USA • APPLICATIONS HOTLINE: 1 (800) 546-2739 4 OPERATING CONSIDERATIONS PA89 • PA89A GENERAL Please read Application Note 1 "General Operating Con- siderations" which covers stability, supplies, heat sinking, mounting, current limit, SOA interpretation, and specification interpretation. Visit www.apexmicrotech.com for design tools that help automate tasks such as calculations for stability, internal power dissipation, current limit; heat sink selection; Apex’s complete Application Notes library; Technical Seminar Workbook; and Evaluation Kits. STABILITY Although the PA89 can be operated at unity gain, maximum slew rate and bandwidth performance was designed to be obtained at gains of 10 or more. Use the small signal response and phase response graphs as a guide. In applications where gains of less than 10 are required, use noise gain compensa- tion to increase the phase margin of the application circuit as illustrated in the typical application drawing. SAFE OPERATING AREA (SOA) The MOSFET output stage of this power operational ampli- fier has two distinct limitations: 1. The current handling capability of the MOSFET geometry and the wire bonds. 2. The junction temperature of the output MOSFETs. NOTE: The output stage is protected against transient flyback. However, for protection against sustained, high energy flyback, external fast-recovery diodes should be used. SAFE OPERATING CURVES The safe operating area curves define the maximum ad- ditional internal power dissipation the amplifier can tolerate when it produces the necessary output to drive an external load. This is not the same as the absolute maximum internal power dissipation listed elsewhere in the specification since the quiescent power dissipation is significant compared to the total. EXTERNAL COMPONENTS The very high operating voltages of the PA89 demand consideration of two component specifications rarely of con- cern in building op amp circuits: voltage rating and voltage coefficient. The compensation capacitance C C must be rated for the full supply voltage range. For example, with supply voltages of ±500V the possible voltage swing across C C is 1000V. In addition, a voltage coefficient less than 100PPM is recom- mended to maintain the capacitance variation to less than 5% for this example. It is strongly recommended to use the highest quality capacitor possible rated at least twice the total supply voltage range. Of equal importance are the voltage rating and voltage coef- ficient of the gain setting resistances. Typical voltage ratings of low wattage resistors are 150 to 250V. In the above example 1000V could appear across the feedback resistor. This would require several resistors in series to obtain the proper voltage rating. Low voltage coefficient resistors will insure good gain linearity. The wattage rating of the feedback resistor is also of concern. A 1 megohm feedback resistor could easily develop 1 watt of power dissipation. Though high voltage rated resistors can be obtained, a 1 megohm feedback resistor comprised of five 200Kohm, 1/4 watt metal film resistors in series will produce the proper voltage rating, voltage coefficient and wattage rating. CURRENT LIMIT For proper operation the current limit resistor (R CL) must be connected as shown in the external connection diagram. The minimum value is 3.5 ohm, however for optimum reliability the resistor value should be set as high as possible. The value is calculated as follows with the maximum practical value of 150 ohms. .7 R CL = I LIM When setting the value for R CL allow for the load current as well as the current in the feedback resistor. Also allow for the temperature coefficient of the current limit which is approxi- mately -0.3% /°C of case temperature rise. CAUTIONS The operating voltages of the PA89 are potentially lethal. During circuit design, develop a functioning circuit at the lowest possible voltages. Clip test leads should be used for “hands off” measurements while troubleshooting. POWER SUPPLY PROTECTION Unidirectional zener diode transient absorbers are recom- mended as protection on the supply pins. The zeners clamp transients to voltages within the power supply rating and also clamp power supply reversals to ground. Whether the zeners are used or not, the system power supply should be evaluated for transient performance including power-on overshoot and power-off polarity reversals as well as line regulation. Conditions which can cause open circuits or polarity reversals on either power supply rail should be avoided or protected against. Reversals or opens on the negative supply rail is known to induce input stage failure. Unidirectional transzorbs prevent this, and it is desirable that they be both electrically and physically as close to the amplifier as possible. ��� ��� ��� ���� ���� ���������������������������������������� ���������� � �� �� ��� ��� � �� �� ����� ���� ���� ����� ����� ���� ���� ��� ��� This data sheet has been carefully checked and is believed to be reliable, however, no responsibility is assumed for possible inaccuracies or omissions. All specifications are subject to change without notice. PA89U REV H MAY 2005 © 2005 Apex Microtechnology Corp. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |