4 / 10 page ![]() Functional Description (Continued) TABLE II Clock RAM Bit Map for Alarm Interrupt Everyday at 1015 am Address Data Function Hi Nibble Lo Nibble 4321076 5 4 32 1 0 Milliseconds 0 1 0 0 0 0 0 0 0 No RAM Exists Hundredths and 0100100 0 0 00 0 0 Tenths of Seconds Seconds 0 1 0 1 0 0 0 0 0 0 0 0 0 Minutes 0 1 0 1 1 0 0 0 1 0 1 0 1 Hours 0 1 1 0 0 0 0 0 1 0 0 0 0 Day of Week 0 1 1 0 1 No RAM Exists 1 1 X X Day of Month 0 1 1 1 0 1 1 X X 1 1 X X Months 0 1 1 1 1 1 1 X X 1 1 X X TABLE III Address Codes and Function A4 A3 A2 A1 A0 Function 0 0 0 0 0 CounterMilliseconds 0 0 0 0 1 CounterHundredths and Tenths of Seconds 0 0 0 1 0 CounterSeconds 0 0 0 1 1 CounterMinutes 0 0 1 0 0 CounterHours 0 0 1 0 1 CounterDay of Week 0 0 1 1 0 CounterDay of Month 0 0 1 1 1 CounterMonth 0 1 0 0 0 RAMMilliseconds 0 1 0 0 1 RAMHundredths and Tenths of Seconds 0 1 0 1 0 RAMSeconds 0 1 0 1 1 RAMMinutes 0 1 1 0 0 RAMHours 0 1 1 0 1 RAMDay of Week 0 1 1 1 0 RAMDay of Month 0 1 1 1 1 RAMMonths 1 0 0 0 0 Interrupt Status Register 1 0 0 0 1 Interrupt Control Register 1 0 0 1 0 Counters Reset 1 0 0 1 1 RAM Reset 1 0 1 0 0 Status Bit 1 0 1 0 1 GO Comand 1 0 1 1 0 STANDBY INTERRUPT 1 1 1 1 1 Test Mode All others unused The comparator is a cascaded exclusive NOR Its output is latched 61 ms after the rising edge of the 1 kHz clock signal (input to the milliseconds counter) This allows the counter to ripple through before looking at the comparator For oper- ation at less than 45V the thousandths of seconds counter should not be included in a compare because of the possi- bility of having a ripple delay greater than 61 ms (For output timing see Interrupt Timing) Power Down Mode The POWER DOWN input is essentially a second chip se- lect It disables all inputs and outputs except for the STANDBY INTERRUPT When this input is at a logical zero the device will not respond to any external signals It will however maintain timekeeping and turn on the STANDBY INTERRUPT if programmed to do so (The programming must be done before the POWER DOWN input goes to a 4 |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |