Back Button WM8802SCFT Datasheet HTML 25Page - Wolfson Microelectronics plc WM8802SCFT Datasheet HTML 26Page - Wolfson Microelectronics plc WM8802SCFT Datasheet HTML 27Page - Wolfson Microelectronics plc WM8802SCFT Datasheet HTML 28Page - Wolfson Microelectronics plc WM8802SCFT Datasheet HTML 29Page - Wolfson Microelectronics plc WM8802SCFT Datasheet HTML 30Page - Wolfson Microelectronics plc WM8802SCFT Datasheet HTML 31Page - Wolfson Microelectronics plc WM8802SCFT Datasheet HTML 32Page - Wolfson Microelectronics plc WM8802SCFT Datasheet HTML 33Page - Wolfson Microelectronics plc Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 65 page
background image
Product Preview
WM8802
w
PP Rev 1.1 April 2004
29
DATA
PLL LOCK
ERROR
INPUT PARITY
ERROR (A)
INPUT PARITY
ERROR (B)
INPUT PARITY
ERROR (C)
RDATA output
Low
Low
Previous value data
Output
fs calculation result
Low
Output
Output
Output
Channel status
Low
Low
Previous value data
Previous value data
Validity flag
Low
Low
Output
Output
User data
Low
Low
Output
Output
Table 11 Data Processing upon Error Occurrence
Notes:
1.
Input parity error (A): Occurs 9 or more times in succession
2.
Input parity error (B): Occurs 8 or fewer times in succession, in case of audio data
3.
Input parity error (C): Occurs 8 or fewer times in succession, in case of non-PCM burst data
Figure 20 shows an example of data processing upon occurrence of a parity error.
RERR
RDATA
R-ch
Previous data value
Input Data
RLRCK
An error occurs a single time
Muted after 9 or more
consecutive errors
L-ch R-ch ….
Previous data value
R-2
L-2
R-0
L-1
R-0
L-0
L-2 R-2 L-2 R-2 L-2 R-2 L-2 R-2
L-4
R-3
L-3
R-2
L-2
R-1
R-4 L-5 R-5 L-6 R-6 L-7 R-7 L-8 R-8
L-1
Figure 20 Data Processing Upon Parity Error Occurrence
PROCESSING DURING ERROR RECOVERY
PLL becomes locked and data demodulation begins when preambles B, M and W are detected.
RDATA output data is output from the RLRCK edge after RERR goes Low.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com