| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ADM1177-1ARMZ-R7 Datasheet(PDF) 14 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1177-1ARMZ-R7 Datasheet(HTML) 14 Page - Analog Devices |
|
14 / 16 page ![]() ADM1177 Preliminary Technical Data Rev. PrD | Page 14 of 16 READ VOLTAGE AND/OR CURRENT DATA BYTES The ADM1177 can be set up to provide information in three different ways (see Write Command Byte section above). Depending on how the device is configured the following data can be read out of the device after a conversion (or conversions): 1. Voltage and Current Readback. The ADM1177 will digitize both voltage and current. Three bytes will be read out of the device in the following format: Table 11. Byte Contents B7 B6 B5 B4 B3 B2 B1 B0 1 Voltage MSBs V11 V10 V9 V8 V7 V6 V5 V4 2 Current MSBs I11 I10 I9 I8 I7 I6 I5 I4 3 Voltage LSBs V3 V2 V1 V0 I3 I2 I1 I0 2. Voltage Readback . The ADM1177 will digitize voltage only. Two bytes will be read out of the device in the following format: Table 12. Byte Contents B7 B6 B5 B4 B3 B2 B1 B0 1 Voltage MSBs V11 V10 V9 V8 V7 V6 V5 V4 2 Voltage LSBs V3 V2 V1 V0 0 0 0 0 3. Current Readback . The ADM1177 will digitize current only. Two bytes will be read out of the device in the following format: Table 13. Byte Contents B7 B6 B5 B4 B3 B2 B1 B0 1 Current MSBs I11 I10 I9 I8 I7 I6 I5 I4 2 Current LSBs I3 I2 I1 I0 0 0 0 0 The following series of events occur when the master receives three bytes (voltage and current data) from the slave device: 1. The master device asserts a START condition on SDA. 2. The master sends the 7-bit slave address followed by the read bit (high). 3. The addressed slave device asserts ACK on SDA. 4. The master receives the first data byte. 5. The master asserts ACK on SDA. 6. The master receives the second data byte. 7. The master asserts ACK on SDA. 8. The master receives the third data byte. 9. The master asserts NO ACK on SDA. 10. The master asserts a STOP condition on SDA and the transaction ends. For the cases where the master is reading voltage only or current only, only two data bytes will be read and events 7 and 8 above will not be required. S SLAVE ADDRESS RA A DATA 1 A P DATA 2 N 12 34 5 6 7 89 10 DATA 3 Figure 12. Three Byte Read fromADM1177 S SLAVE ADDRESS RA A REGISTER ADDRESS P REGISTER DATA N 12 34 5 6 78 Figure 13. Two Byte Read fromADM1177 Read Status Register A single register of status data can also be read from the ADM1177. 1. The master device asserts a START condition on SDA. 2. The master sends the 7-bit slave address followed by the read bit (high). 3. The addressed slave device asserts ACK on SDA. 4. The master receives the status byte. 5. The master asserts ACK on SDA. S SLAVE ADDRESS RA A DATA 1 12 34 5 Figure 14. Status Read fromADM1177 Table 14 shows the ADM1177 status registers in detail. Note that bits 1, 3 and 5 are cleared by writing to bit 4 of the ALERT_EN register (CLEAR). |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |