| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ADE7953ACPZ Datasheet(PDF) 66 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7953ACPZ Datasheet(HTML) 66 Page - Analog Devices |
|
66 / 68 page ![]() ADE7953 Data Sheet Rev. A | Page 66 of 68 Interrupt Enable and Interrupt Status Registers Current Channel A and Voltage Channel Registers Table 22. IRQENA Register (Address 0x22C and Address 0x32C) Bits Bit Name Description 0 AEHFA Set to 1 to enable an interrupt when the active energy is half full (Current Channel A) 1 VAREHFA Set to 1 to enable an interrupt when the reactive energy is half full (Current Channel A) 2 VAEHFA Set to 1 to enable an interrupt when the apparent energy is half full (Current Channel A) 3 AEOFA Set to 1 to enable an interrupt when the active energy has overflowed or underflowed (Current Channel A) 4 VAREOFA Set to 1 to enable an interrupt when the reactive energy has overflowed or underflowed (Current Channel A) 5 VAEOFA Set to 1 to enable an interrupt when the apparent energy has overflowed or underflowed (Current Channel A) 6 AP_NOLOADA Set to 1 to enable an interrupt when the active power no-load condition is detected on Current Channel A 7 VAR_NOLOADA Set to 1 to enable an interrupt when the reactive power no-load condition is detected on Current Channel A 8 VA_NOLOADA Set to 1 to enable an interrupt when the apparent power no-load condition is detected on Current Channel A 9 APSIGN_A Set to 1 to enable an interrupt when the sign of active energy has changed (Current Channel A) 10 VARSIGN_A Set to 1 to enable an interrupt when the sign of reactive energy has changed (Current Channel A) 11 ZXTO_IA Set to 1 to enable an interrupt when the zero crossing has been missing on Current Channel A for the length of time specified in the ZXTOUT register 12 ZXIA Set to 1 to enable an interrupt when the current Channel A zero crossing occurs 13 OIA Set to 1 to enable an interrupt when the current Channel A peak has exceeded the overcurrent threshold set in the OILVL register 14 ZXTO Set to 1 to enable an interrupt when a zero crossing has been missing on the voltage channel for the length of time specified in the ZXTOUT register 15 ZXV Set to 1 to enable an interrupt when the voltage channel zero crossing occurs 16 OV Set to 1 to enable an interrupt when the voltage peak has exceeded the overvoltage threshold set in the OVLVL register 17 WSMP Set to 1 to enable an interrupt when new waveform data is acquired 18 CYCEND Set to 1 to enable an interrupt when it is the end of a line cycle accumulation period 19 Sag Set to 1 to enable an interrupt when a sag event has occurred 20 Reset This interrupt is always enabled and cannot be disabled 21 CRC Set to 1 to enable an interrupt when the checksum has changed Table 23. IRQSTATA Register (Address 0x22D and Address 0x32D) and RSTIRQSTATA Register (Address 0x22E and Address 0x32E) Bits Bit Name Description 0 AEHFA Set to 1 when the active energy register is half full (Current Channel A) 1 VAREHFA Set to 1 when the reactive energy register is half full (Current Channel A) 2 VAEHFA Set to 1 when the apparent energy register is half full (Current Channel A) 3 AEOFA Set to 1 when the active energy register has overflowed or underflowed (Current Channel A) 4 VAREOFA Set to 1 when the reactive energy register has overflowed or underflowed (Current Channel A) 5 VAEOFA Set to 1 when the apparent energy register has overflowed or underflowed (Current Channel A) 6 AP_NOLOADA Set to 1 when the active power no-load condition is detected Current Channel A 7 VAR_NOLOADA Set to 1 when the reactive power no-load condition is detected Current Channel A 8 VA_NOLOADA Set to 1 when the apparent power no-load condition is detected Current Channel A 9 APSIGN_A Set to 1 when the sign of active energy has changed (Current Channel A) 10 VARSIGN_A Set to 1 when the sign of reactive energy has changed (Current Channel A) 11 ZXTO_IA Set to 1 when a zero crossing has been missing on Current Channel A for the length of time specified in the ZXTOUT register 12 ZXIA Set to 1 when a current Channel A zero crossing is detected 13 OIA Set to 1 when the current Channel A peak has exceeded the overcurrent threshold set in the OILVL register 14 ZXTO Set to 1 when a zero crossing has been missing on the voltage channel for the length of time specified in the ZXTOUT register 15 ZXV Set to 1 when the voltage channel zero crossing is detected 16 OV Set to 1 when the voltage peak has exceeded the overvoltage threshold set in the OVLVL register |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |