90 / 114 page ![]() Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, analog adjustable 7/90 Siemens LV 1 T · 2006 ■Overview The 3RS10/3RS11 analog temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensors in the medium, evaluated by the device and monitored for overshoot or undershoot. When the threshold values are reached, the output relay switches on or off depending on the setting. ■Technical specifications 1) 2-wire connection of resistance sensors with wire jumper between T2 and T3. Type 3RS10 00 3RS10 10 3RS11 00 3RS11 01 3RS10 20 3RS10 30 3RS11 20 3RS11 21 General data Sensor type PT100 TC type J TC type K PT100 TC type J TC type K Width mm 22.5 Operating range 0.85 ... 1.1 x Us Rated power W/VA < 2/4 Auxiliary circuits Contacts 1 NO + 1 NC 1 CO + 1 NO Rated operational currents Ie • AC-15 at 230 V, 50 Hz A 3 • DC-13 at: - 24 V AC A 1 - 240 V AC A 0.1 DIAZED fuse • gl/Gg operational class A 4 Short-circuit current (at 250 V) kA 1 Electrical endurance AC-15 at 3 A 100000 Mechanical endurance Mechanical operating cycles 3 x 106 Tripping units • Measuring accuracy at 20 °C ambient temperature (T20) Typical < ±5 % from upper limit of scale • Reference point accuracy -- < 5 K -- < 5 K • Deviations due to ambient temperature in % from measuring range < 2 < 3 < 2 < 3 • Hysteresis settings - For temperature 1 2 ... 20 % from upper limit of scale - For temperature 2 5 % from upper limit of scale Sensor circuits • Typical sensor circuits - PT100 mA Typical 1 -- Typical 1 -- - PT1000 mA Typical 0.2 -- Typical 0.2 -- • Open-circuit detection No • Short-circuit detection No • 3-wire conductor connection1) Yes -- Yes -- Enclosures Environmental influences Permissible ambient temperature °C -25 ... +60 Permissible storage temperature °C -40 ... +80 Permissible mounting position any Degree of protection acc. to EN 60529 Terminals: IP20; Cover: IP40 Rated insulation voltage Ui (pollution degree 3) V 300 Conductor cross-section • Screw-type connection M 3.5 (standard screwdriver, size 2 and Pozidriv 2) - Solid mm2 1 x (0.5 ... 4)/2 x (0.5 ... 2.5) - Finely stranded, with end sleeve mm2 1 x (0.5 ... 2.5)/2 x (0.5 ... 1.5) - AWG conductors, solid or stranded AWG 2 x (20 ... 14) - Tightening torque Nm 0.8 ... 1.2 • Spring-loaded terminal - Solid mm2 2 x (0.25 ... 1.5) - Finely stranded, with end sleeve mm2 2 x (0.25 ... 1) - Finely stranded, without end sleeve mm2 2 x (0.25 ... 1.5) - AWG conductors, solid or stranded AWG 2 x (24 ... 16) - Corresponding opening tool 8WA2 807 Vibration resistance acc. to IEC 68-2-6 Hz/mm 5 ... 26/0.75 Shock resistance to IEC 68-2-27 g/ms 15/11 |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |