37 / 41 page ![]() MS1003SH・MS1004SH Application Note Ver.2.2 SHINDENGEN ELECTRIC MFG. CO. , LTD 37/41 (6) Calculating the number of turns in the control coil Formula 15: 6 . 0 12 8 . 0 15 8 Nc =10.03[Turn] Round the result to the nearest integer, i.e., Nc = 10 turns. (Round up the result when adjusting the voltage upwards. When adjusting it downwards, round it down.) (7) Recalculating the transformer design The actual design values of a transformer differ from initial design values because results are rounded to integers during the design process and because actual resistances and inductances differ from calculations. The differences are corrected and the OCL resistance R(OCL) and transformer core gap are determined as follows: 1) Correcting the main SW peak current and determining OCL resistance R(OCL) Calculate R(OCL) based on the relationship between the main SW peak current obtained in Section (3) and the VTH (OCL) clamp. 484 . 1 54 . 0 ) ( OCL R =0.3638[Ω] To adjust resistance, change R(OCL) to 0.37 Ω (e.g., 0.22 Ω + 0.15 Ω). The main SW peak current changes to 37 . 0 54 . 0 DP I =1.46[A]. 2) Determining the core gap and correcting the inductance To specify the core gap when ordering a transformer, you can use the result of Formula 12 in Section 5.3. Note that using the inductance coefficient “AL-value” is more common. The AL-value is among the key parameters that determine transformer core performance, together with the NI-limit expressed in [ 2 N nH ] and magnetic saturation condition. The inductance is corrected based on the assumption that the AL-value is 140. (Standard AL-values vary from manufacturer to manufacturer. Contact the transformer manufacturer to obtain more information.) Since the 2 value - AL N nH , the result is 2 68 140 = 647360 nH. The inductance Lp is corrected to 0.647 mH. 3) Correcting initial design values From the IDP and Lp obtained in Sections 1) and 2), the initial design values are corrected as follows: Formula 10: 102 46 . 1 10 647 . 0 3 (min) 1 (max) DC DP on V I Lp t =9.26 [μs] |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |